What tools are needed for installation?
Pipe Wrench
Adjustable Wrench
Drill
Tape Measure
10" x 5/16" Nut Driver
Thread Sealant
Level
2-1/2" Diameter Hole Saw for 2" pipe
2" Diameter Hole Saw for 1-1/2" pipe
1" Diameter Hole Saw
Non-corrosive Leak Check Solution
Where will the wall furnace be installed?
•
On the Floor - Wall Furnace comes equipped from
factory for this option. See Page 21.
•
Wall Mounted - Wall mount shroud needed. See
Page 15 for kit number.
•
Mount wall furnace at a height so that the con-
trols can still be observed.
•
Interior Wall - Maximum vent length is 50 feet.
•
Exterior Wall
•
Locate Electrical Supply - Extension cords may
NOT be used.
•
Wall Furnace Dimensions page 16.
•
Clearances to Combustibles page 17.
What kind of venting application will be used?
•
Single Flue - Wall Furnace comes equipped from
factory for this option. A 2" or 1-1/2" pipe may be
used. If a 1-1/2" pipe is used, it must be enlarged to
a 2" pipe prior to exiting the wall into the shroud.
•
Direct Vent - An "Air Pipe Kit" is required and is
available for order. See page 15.
How will the venting be run?
•
Straight out the back - Wall Furnace comes
equipped from factory for this option. Standard Rear
Shroud supplied. See page 27.
•
In Front of the wall - Deep Shroud needed. Venting
option may NOT be done in Wall Mount installations.
See page 15 for kit number.
•
Venting Guidelines pages 25 to 32.
•
Maximum vent length is 50 feet.
•
Notice: Clean all debris from the inside of the flue
pipe prior to applying the glue and final assembly
of the pipe. Since the condensate is designed to
flow back to the appliance this debris will be carried
to the condensate trap resulting in a clog. An "A2"
error will appear on the display panel if this happens.
The clog, and the work required to fix it, can be eas-
ily prevented by pulling a wet cloth through the pipe
prior to applying the glue and final assembly.
Page 14
INTRODUCTION
FAQ - INSTALLATION CONSIDERATIONS
How will the condensate be disposed?
•
To a drain - Wall Furnace comes equipped from the
factory to drain up to 3 feet away from the appliance.
•
An Extension Kit and External Condensate Pump
kit may also be used. See page 15 for kit numbers.
•
Humidification - Optional Heated Humidification Tray
Kit available for order. See page 15 for kit number.
•
Winterization information on page 41.
How will the wall furnace be operated?
•
Remote - external Millivolt thermostat, wall switch or
remote control. See page 15 for kits available from
Empire Comfort Systems.
Manual - use the display panel to control the heating
•
level and turn the wall furnace on and off.
•
Local (Internal Thermostatic) - Factory installed
temperature probe on the wall furnace with a built-
in thermostatic function to control the wall furnace's
operation.
•
If it is desired to use the temperature sensed in
another part of the room, a wired temperature
probe accessory kit is available. See page 15 for
kit numbers.
•
See Operation Instructions pages 7 to 12.
•
Notice: Following a power outage, this wall furnace
will not automatically resume operation when oper-
ated manually or with the internal thermostat. Once
power is restored, the wall furnace will automatically
power on in "Remote Mode" (--), and the original op-
eration settings will need to be re-entered. Installing
an optional Millivolt thermostat control allows the wall
furnace to automatically resume operation under that
thermostat's control once power is restored. Ask your
dealer for details.
37873-0-0217