WARNING: If the information in these instructions are
not followed exactly, a fire or explosion may result caus-
ing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appli-
ance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLATION INSTRUCTIONS
OWNER'S MANUAL
AND
FAN TYPE
DIRECT VENT
WALL FURNACE
MODEL
DV-55-1SPP
Installer:
Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
WARNING: If not installed, operated and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by state or local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is used.
Page 1

Publicité

loading

Sommaire des Matières pour Empire Heating Systems DV-55-1SP

  • Page 1 INSTALLATION INSTRUCTIONS OWNER'S MANUAL FAN TYPE DIRECT VENT WALL FURNACE MODEL DV-55-1SPP Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. WARNING: If not installed, operated and maintained WARNING: If the information in these instructions are in accordance with the manufacturer's instructions, not followed exactly, a fire or explosion may result caus- this product could expose you to substances in fuel...
  • Page 2 TABLE OF CONTENTS SECTION PAGE Important Safety Information ..................3 Safety Information for Users of LP Gas ..............4 Requirements for Massachusetts ................5 Introduction ......................6 Specifications ......................6 Gas Supply ......................7-8 Clearances ......................8 Installation Instructions ..................9-11 Lighting Instructions ....................12 Pilot Flame Characteristics ...................13 Main Burner Flame Characteristics ...............13 Wiring ........................14 Service and Maintenance Suggestions ..............15...
  • Page 3 IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • Due to high temperatures the appliance should be • DO NOT put anything around the furnace that will located out of traffic and away from furniture and obstruct the flow of combustion and ventilation air.
  • Page 4 SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires SOME POINTS TO REMEMBER and explosions. In its natural state, propane is odorless and • Learn to recognize the odor of LP-gas. Your local LP-Gas colorless.
  • Page 5 REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed SIGNAGE. A metal or plastic identification plate shall be per- in every dwelling, building or structure used in whole or in part for manently mounted to the exterior of the building at a minimum residential purposes, including those owned or operated by the height of eight (8) feet above grade directly in line with the Commonwealth and where the side wall exhaust vent termination...
  • Page 6 INTRODUCTION Introduction Installation in Residential Garages Always consult your local Building Department regarding regula- Gas utilization equipment in residential garages shall be installed tions, codes or ordinances which apply to the installation of a direct so that all burners and burner ignition devices are located not less vent wall furnace.
  • Page 7 GAS SUPPLY Locating Gas Supply checked for leaks by the installer. This should be done with a soap The gas line can enter the unit either through the floor or outside solution watching for bubbles on all exposed connections, and if wall.
  • Page 8 GAS SUPPLY Checking Manifold Pressure Both Propane and Natural gas valves have a built-in pressure regulator in the gas valve. Natural gas models will have a manifold pressure of approximately 4.0" w.c. at the valve outlet with the inlet pressure to the valve from a minimum of 6.0" w.c. for the purpose of input adjustment to a maximum of 7.0"...
  • Page 9 INSTALLATION INSTRUCTIONS Locating Wall Opening The furnace is to be located on an outside wall. Locate wall studs so that wall opening will be located between wall studs. The furnace is 16 inches in width and normal 16 inches on center studs will not allow the furnace to be recessed into the wall unless a stud is repositioned.
  • Page 10 INSTALLATION INSTRUCTIONS (continued) Cutting Vent Tubes This is the most important part of the installation. With the furnace installed on wall the 6" diameter air inlet tube and the 4" diameter flue outlet tube are to be marked and cut using the following procedure. Attach 6"...
  • Page 11 INSTALLATION INSTRUCTIONS (continued) Installing a Vent Near a Window Ledge, Warning: When vinyl siding vent kit, DV-822 or 2" x 4" fram- Other Type of Projection or on Siding (vinyl, aluminum, etc.) ing is added to an existing installation (furnace is installed) Direct vent furnaces are designed to be installed on a uniform out- side wall.
  • Page 12 LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. C.
  • Page 13 PILOT FLAME CHARACTERISTICS PROPER FLAME ADJUSTMENT The correct pilot flame (Figure 11) will be blue, extending past the thermocouple. The flame will surround the thermocouple just below the tip. Natural gas pilots require adjusting when the inlet gas pressure is above 5"...
  • Page 14 WIRING Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized. This appliance is equipped with a three- prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 15 SERVICE & MAINTENANCE SUGGESTIONS Replacing Fan and Oiling the Motor If Electrode Does Not Produce Spark: The fan motor should be cleaned and oiled once each heating season. Check wire connections. To reach the motor, withdraw the metal shroud surrounding the fan Check gap for pilot burner to the electrode tip.
  • Page 16 PARTS LIST PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. Index Part No. Description Index Part No. Description 11762 Outer Casing Top DV064 Cover Plate for Observation Hole R618 Motor Mount (Four Required) DV775 Seal Bracket 11764...
  • Page 17 PARTS VIEW 32188-4-0814 Page 17...
  • Page 18 MASTER PARTS DISTRIBUTOR LIST To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com. To provide war- ranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit. To Order Parts After the Warranty Period, please contact your dealer or one of the Master Parts Distributors listed below.
  • Page 19 WARRANTY Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods specified below. Space heating products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.
  • Page 20 Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. Comfort Systems www.empirecomfort.com Page 20 32188-2-0814...
  • Page 21 INSTRUCTIONS POUR L’INSTALLATION MANUEL DU PROPRIÉTAIRE RADIATEUR MURAL À CIRCULATION FORCÉE AVEC UN ÉVENT DIRECT MODÈLES DV-55SPP AVERTISSEMENT: Assurez vous de bien suiv- re les instructions données dans cette notice Installateur: Laissez cette notice avec l’appareil. pour réduire au minimum le risque d’incendie Consommateur: Conservez cette notice pour ou d’explosion ou pour éviter tout dommage consultation ultériure.
  • Page 22 Introduction Installation sur un Tapis ou Tuile Toujours consulter le département de construction de votre région en ce Si cet appareil est installé directement sur un tapis, tuiles ou tout genre qui regarde les règlements, les codes ou les ordonnances qui s’appliquent de matériel combustible autre qu’un plancher de bois, cet appareil doit à...
  • Page 23 INFORMATION DE SÉCURITÉ POUR LES UTILISATEURS DE PROPANE Le propane est un gaz inflammable qui peut causer des feux et des famille. Un jour, lorsqu’il n’y aura pas une minute à perdre, la explosions. Dans son état naturel, le propane est inodore et sans sécurité...
  • Page 24 Emplacement de l'Ouverture dans le Mur DV-822 L’assemblage d’évent pour le revêtement en vinyle Le radiateur doit être situé sur un mur extérieur. Trouver les montants du mur, ainsi l’ouverture dans le mur sera entre les Agence d’Installation Qualifiée montants du mur. Le radiateur a une largeur de 16" (40.64cm) et L’installation et le remplacement des tuyaux à...
  • Page 25 pour la sortie d’air et marquer les trous de montage en MINIMUM 4" (10.16cm) MINIMUM 4" (10.16cm) AUX MATÉRIAUX AUX MATÉRIAUX utilisant le registre comme guide. COMBUSTIBLES COMBUSTIBLES 10. Percer (2) trous de 1/8" (3.2mm) de diamètre dans le mur et attacher le registre avec (2) vis #10 x 1"...
  • Page 26 Emplacement de l'Alimentation Électrique sur le collet de la sortie d’échappement qui est sur la chambre Sur le bas des panneaux des côtés gauche et droit, il y a une entrée de combustion. Soyez certain que le tuyau d’échappement de défonçable de 7/8"...
  • Page 27 CALFEUTRER d’échappement de 4" (10.16cm) de diamètre et sur le collet CALFEUTRER de 4" (10.16cm) de diamètre du capuchon d’évent. Attacher PLAQUE EX- PLAQUE EX- TÉRIEURE DE le tuyau de sortie d’échappement de 4" (10.16cm) de TÉRIEURE DE MONTAGE MONTAGE diamètre au collet de la sortie d’échappement de la chambre de combustion.
  • Page 28 BONDE NPT DE 1/8" (3.175mm) POUR VÉRIFIER LE JAUGEAGE DES TUYAU D’ALIMENTATION VALVE VUE DE DESSUS CONNEXIONS. EN GAZ RÉGULATEUR DE PRESSION ÉVENT VALVE À PRISE POUR SORTIE DE CLÉ UNIVERSELLE VALVE DE FERMETURE PRESSION MANUELLE RACCORD HORIZONTAL ENTRÉE DE GAZ SORTIE DE GAZ ARRIVÉE PRISE POUR PRESSION...
  • Page 29 AJUSTEMENT CONVENABLE DE LA FLAMME lorsqu’il est installé, doit avoir une prise de terre conforme avec les codes locaux ou dans l’absence de codes locaux, avec le National Electrical Code, ANSI/NFPA70 ou Canadian Electrical Code, CSA C22.1. Pour votre protection contre les dangers de chocs, cet appareil FAIRE UNE INSPECTION VISUELLE est muni d’une fiche à...
  • Page 30 POUR VOTRE SÉCURITÉ LIRE AVANT D’ALLUMER AVERTISSEMENT: Si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. A. Cet appareil a une veilleuse qui doit être allumée manuel- instructions du fournisseur de gaz.
  • Page 31 SUGGESTIONS POUR LE SERVICE ET L’ENTRETIEN. APPELER UN TECHNICIEN D’ENTRETIEN GÉNÉRAL : Tous les radiateurs ont reçu un test d’allumage ment ouvert ( dans le sens opposé des aiguilles d’une montre pour vérifier le bon fonctionnement. Ceci inclus la flamme du pour "ouvert").
  • Page 32 S’IL VOUS PLAÎT NOTER: Lorsque vous commandez les pièces, il est très important que le numéro de la pièce et la description coïncident. Numéro Numéro de Numéro Numéro de Description Description d’index la pièce d’index la pièce 11763 Dessus de la paroi extérieure Joint d’étanchéité...
  • Page 33 Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62220-2623 32188-4-0814 Page 13...
  • Page 34 GARANTIE Empire Comfort Systems Inc. garantit que ce produit de chauffage individuel est exempt de défauts au moment de son achat et pen- dant les périodes indiquées ci-dessous. Les produits de chauffage individuel doivent être installés par un technicien qualifié et doivent être entretenus et utilisés de façon sécuritaire, en conformité...
  • Page 35 NOTES DE SERVICE 32188-4-0814 Page 15...
  • Page 36 Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez contacter votre revendeur. Comfort Systems www.empirecomfort.com Page 16 32188-2-0814...