Introduction - Empire Heating Systems FAW55IPXLP-1 Instructions D'installation Et Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Introduction

Always consult your local Building Department regarding regulations,
codes or ordinances which apply to the installation of a vented
wall furnace.
Instructions to Installer
1.
Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail warranty card supplied
with furnace.
3.
Installer should show owner how to start and operate furnace.
Any change to this furnace or its control can be dangerous.
This is a heating appliance and any panel, door or guard
removed for servicing an appliance must be replaced prior
to operating the appliance.
General Information
This series is design certified in accordance with American National
Standard / CSA Standard Z21.86 and CSA 2.32 by the Canadian
Standards Association, as a Fan Type Vented Wall Furnace and
must be installed according to these instructions.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not
shown on the rating plate is the responsibility of the person
and company making the change.
Important
All correspondence should refer to complete Model No., Serial No.
and type of gas.
ACCESSORIES
Part No.
SOR-1
Register, side outlet, fixed register
SOK-1
Side outlet, 10" (254mm) maximum extension, fixed
register
ROK-1
Rear Outlet, 10" (254mm) maximum extension,
adjustable register
DV-651
Vent enclosure, 14" (356mm) [for room up to 96
1/2" (245cm) in height]
DV-665
Vent enclosure, 24" (610mm) [for rooms up to 106
1/2" (270.5cm) in height]
DV-666
Vent enclosure, 36" (914mm) [for rooms up to 118
1/2" (301cm) in height]
DV-648
4" (102mm) Oval-to-Round flue adapter kit
CONVERSION KITS
Part Number
Description
682160
Propane to Natural
682269
Natural to Propane
37405-4-0519
INTRODUCTION
WARNING
Description
Used On
FAW55IPXLP-1
FAW55IPXNAT-1
Notice: During initial firing of this unit, its paint will bake out and
smoke will occur. To prevent triggering of smoke alarms, ventilate
the room in which the unit is installed.
Installation on Rugs and Tile
If this appliance is installed directly on carpeting, tile or other
combustible material other than wood flooring the appliance shall
be installed on a metal or wood panel extending the full width and
depth of the appliance.
The base referred to above does not mean the fire-proof base as
used on wood stoves. The protection is for rugs that are extremely
thick and light colored tile.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed
so that all burners and burner ignition devices are located not less
than 18" (457mm) above the floor.
Such equipment shall be located, or protected, so it is not subject
to physical damage by a moving vehicle.
Specifications
Model
BTU/hR (KW/h)
height
Width
Depth
Gas Inlet
Vent Collar
CFM
FAW-55IP
55,000 (16.1)
82 3/8" (2092mm)
16" (406mm)
11 1/2" (292mm)
1/2" (13mm) Pipe
4" (102mm) Type B Oval
400
Page 3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Faw55ipxnat-1

Table des Matières