Safety devices
Pressure switch: monitors
depression in the smoke
duct. It is designed to
shut
down
the
feed screw in the event
of an obstructed fl ue or
signifi cant
back-pressure
in the presence of wind.
At the time of the pressure
switch will show " " A L A R -
A L A R -
D E P - F A I L " " .
D E P - F A I L
Electrical
safety:
stove is protected against
violent surges of current
(ex. lightnings) by the main
fuse 4 A which is located
on the control panel at
the rear of the stove.
Other fuses to protect the
electronic boards are to
be found on the boards
themselves.
Tampering with the safety devices is prohibited. It is only after eliminating the
cause which gave rise to the intervention of the safety system, that it is possible to
relight the stove and thus reset the automatic operation of the sensor. To understand
which anomaly has occurred, consult this manual at paragraph relating to alarms
which explains what to do based on the alarm message the stove display.
26
Reduction motor: if the
motor stops, the stove
continues
pellet
until the fl ame goes out
for lack of fuel, and until
It has cooled down to the
minimum level.
RESTART
the
Pellets
safety:
event there is a too high
temperature in the tank,
the thermostat for pellets
safety with manual reset
creates an alarm "A L A R -
S I C - F A I L " stopping the
S I C - F A I L
pellet boiler stove. You
need to reset the system
working on the device
placed on the back of the
stove.
to
function
PELLET
temperature
In
the
rare
A L A R -
Flue gas temperature
sensor: thermocouple that
measures the temperature
of the fumes while keeping
the operation or shuts the
stove when the fl ue gas
temperature drops below
the preset value.
Microswitch pellet door:
opening the door load
pellet stove off the power
of the pellet and it remains
open for more than 120"
switches off the stove for
the error "A L A R - D E P -
A L A R - D E P -
F A I L "
F A I L
.