Stand-by Mode
This mode allows the automatic shutdown of the stove once it reaches the temperature set on SET.
When this happens, the stove will wait a few minutes (factory setting), after which will turn off automa-
tically if the temperature of the room in the meantime has always maintained above the set.
Once turned off as a result of this condition, the stove will automatically turn on only when the ambient
temperature will drop to 2 °C below the set temperature in the oven (example: SET=24 °C and ambient
temperature = 21 °C).
If the stove is turned off for the sleep-mode, although there is an ignition programmed this will be igno-
red and the heater will turn back on only to lower the temperature as explained above.
The sleep timer is instead always respected if the stove is in STAND-BY and is turned off manually by
pressing the OFF button; doing so the stove will shut down permanently rekindling not more, less than
expected from the ignition weekly programming.
Enabling stand-by mode
Press the SET (3) to access the menu and with the button
MODE"). Then press SET (3) to access it; STAND-BY function is set by default to OFF. To activate
MODE"). Then press SET (3) to access it; STAND-BY function is set by default to OFF. To activate
this feature, press
fi rm and then OFF (4) to leave. The STAND-BY mode is now active.
External thermostat
The stove has the possibility to interface with an external thermostat for controlling the switching on
and switching off of the heater based on the room temperature. IThe thermostat must be of the open
/ closed type with a clean contact.
If the thermostat carries voltage to the card causing faults, the warranty will expire.
To confi gure the thermostat, simply remove the jumper on the Therm clamp and connect the room
thermostat.
OPERATION BY A SPECIALIZED TECHNICIAN
Once switched on, the stove will remain in operation until the temperature set in the thermostat is
reached.
When the contact is opened the stove will remain in modulation and the display will show ECO THERM
for 5 minutes, after which it will go to Stand-by ECO + OFF.
At the moment of a new heat request in the room (and therefore re-closing of a contact), the stove will
remain in ECO ATT mode for 10 minutes. If during this time the contact remains closed, the stove will
switch on.
REMARKS:
At the moment when the stove will be switched off manually or by programming, it will no longer be
connected by the thermostat.
20
(1), on the display you will see "STAN-BY MODE ON". Press SET (3) to con-