Alarm signals
In the event of a working defect, the system informs the user about the type of failure occurred.
The following table summarises the alarms, kind of problem and possible solution:
Display
ALAR 1
BLACK OUT There is no power supply
PROBE
ALAR 2
EXHAUST
HOT
ALAR 3
EXHAUST
FAN
ALAR 4
FAILURE
NO
ALAR 5
LIGHTIN
NO
ALAR 6
PELLET
SAFETY
ALAR 7
THERMAL
FAILURE
ALAR 8
DEPRESS
SERV
Regular checks should be carried out by the user, who should only contact the Authorized As-
sistance Center if no solution is found.
Kind of problem
The smokes sensor is broken or
not connected to the pcb
Smokes temperature too high
Smokes extractor blocked or
broken
The Stove cannot start up
This is the first light-up
The pellet Stove switched off
while working
The water temperature ex-
ceeds 90°C. The circulating
pump is blocked or there is no
water in the hydraulic system
Obstructed flue
The Stove has worked for 1300
hours. Supplementary mainte-
nance required
Solution
As soon as the power supply is back, the Sto-
ve starts a cooling cycle. After completing the
cycle it starts working automatically
Contact an Authorized Assistance Center
Switch off the Stove, allow it to cool down and
perform ordinary cleaning. If the problem per-
sists, contact an Authorized Assistance Center
for cleaning the Stove and the flue
Contact an Authorized Assistance Center
Fill in the tank with pellets
Start up again
Fill in the tank with pellets
Check the power supply on the pump.
Check limestone does not block the pump
impeller
Clean the flue or check there are no obstructed
grids near the smokes exhaust
Contact an Authorized Assistance Center
21

Publicité

loading

Ce manuel est également adapté pour:

98 elipse 12 c98 supreme 10 c