Operation
Switching on the device
For the illustrations, refer to the graphics
page
If the main switch springs back to position 0
when the device is switched on then the po-
larity at the unit plug is incorrect. Change
the polarity at the unit plug.
Illustration C
1. Connect the mains plug.
2. Switch on the device at the main switch.
Illustration D
Wet vacuum cleaning operation
ATTENTION
Risk of damage if the dirt receptacle
overflows
The dirt receptacle can fill within a few sec-
onds and overflow when vacuuming large
amounts of liquids.
Continuously monitor the filling level.
1. Perform vacuuming.
2. Regularly check the filling level in the dirt
receptacle.
3. Empty the vacuum cleaner waste con-
tainer as necessary.
4. Clean or replace the filter as necessary.
Dry vacuuming operation
DANGER
Damage to the skin, lungs and eyes
through fine dust
Expulsion of fine dust due to a filter that is
no longer permissible
If the device has previously been used for
wet vacuum cleaning, the filter used for this
(wet or dried) is no longer suitable for dry
vacuuming.
Replace the filter with a new, dry filter.
1. Perform vacuuming.
2. Clean or replace the filter as necessary.
Cleaning the filter
A pressure gauge showing the vacuum in-
side the device is mounted on the front of
the device. If the vacuum is greater than the
value specified in the table, then the filter
must be cleaned/replaced.
16
IVS 100 / 55
IVS 100 / 75
1 Switch off the device at the "ON/OFF
switch".
2 Move the filter cleaning lever back and
forth several times.
If this cleaning does not result in an im-
provement, the filter must be removed or
replaced, see chapter Changing/replacing
the filter.
Emptying the vacuum cleaner waste
1. Switch off the device.
2. Secure the device using the parking
brakes on the steering rollers.
3. Open the lock on the vacuum cleaner
waste container upwards.
4. Pull the vacuum cleaner waste container
out of the device.
5. Empty the vacuum cleaner waste con-
tainer.
DANGER
Tipping the waste container while trans-
porting it
Tipping the waste container while trans-
porting it can lead to injuries.
The vacuum material container can be lift-
ed by cranes at the handle. The maximum
load for crane transport is 50 kg.
Be aware of the permissible total weight of
the waste container when transporting it
with a crane and adhere to the applicable
legal regulations.
English
NW 42
NW 52 NW 72
19.5 kPA 18 kPA 10 kPA
28 kPA
24 kPA 13 kPA
container

Publicité