free of cost, provided that a material or
manufacturing defect is the cause. In a war-
ranty case, please contact your dealer (with
Electrical connection
Mains voltage
Power frequency
Degree of protection
Protection class
Maximum permissible mains grid im-
pedance
Nominal power
Power input (normal operation)
Fuse protection
Characteristic of the fuse
Dimensions and weights
Typical operating weight
Length x width x height
Cable length
Nominal width of the suction hose
Ambient conditions
Storage temperature
Relative humidity
Device performance data
Tank content
Air quantity (max.)
Vacuum (max.)
Filter area
Determined values in acc. with EN 60335-2-69
Hand-arm vibration value
Sound pressure level
Uncertainty K
Surface temperature (max.)
Ignition protection class
Mains cable
H07BQ-F
Part number (EU)
Subject to technical modifications.
20
the purchase receipt) or the next author-
ised customer service site.
(See overleaf for the address)
Technical data
IVS 100/55 M Z22 IVS 100/75 M Z22
V
400
Hz
3~ 50
IP 65
I
Ω
0.156+j0.098
W
5500
W
6220
A
16
C
kg
157
mm
1202x686x1495
m
8,2
NW DN72
°C
-10 ... +40
%
30-90
l
100
3
m
/h
353
kPa (mbar) 23,5
2
m
2
2
m/s
<2,5
dB(A)
77
dB(A)
2
°C
125,0
II 3D EX tc IIIC
T125 °C Dc
2
mm
5 x 2,5
9.988-768.0
English
400
3~ 50
IP 65
I
0.400+j0.250
7500
6080
32
B/C
174
1202x686x1495
8,2
NW DN72
-10 ... +40
30-90
100
373
30,5
2
<2,5
73
2
125,0
II 3D EX tc IIIC
T125 °C Dc
5 x 2,5
9.988-767.0