8 Motor stroke learning
1. Scroll down the parameters with
2. Access the parameter by pressing the
3. When "
" flashes, continue pressing the
4. Release the
key when "
the power supply, inverse the operator cables and repeat the operation);
5. Wait for the door (or doors in case of using 2 motors) searches and stops on the opening stop and then on the closing stop.
If you want to anticipate the stopping strokes in opening, you can manually intervene by giving an impulse to "Start" button (or
pressing the "OK" on the control panel) simulating the stroke.
6. Once the procedure is ended, the display will show "- - - - ".
WARNING (only Type 01 and Type 03) Once you have executed the learning stroke, operate a complete cycle (opening/closing) and then
check the manual release to make sure it is working properly. If it's to "hard" increase the value of P057 of 1 or more.
9 Transmitters learning
9.1 Transmitters coding selection
1. Scroll down the parameters with
P027;
2. Confirm by pressing on the
3. Select the type of transmitter by scrolling
- d000=fix rolling-code (suggested);
- d001=complete rolling-code;
- d002=dip-switch;
4. Confirm by pressing on the
Warning: If you need to vary the type of encoding, and only if other remo-
tes with different encoding are memorized, you need to erase memory
(P004) AFTER you have set the new encoding.
and
keys until you visualise P003;
key;
key;
" stops flashing; Start the learning procedure with operator 1 opening (if it starts closing, disconnect
and
keys until you visualise
key;
and
keys:
key (display shows again P027).
37