4 Selection operating with or without encoder
Warning: Remember to correctly set the jumpers J5 and J9.
1. Scroll down the parameters with
lise P029;
2. Access the parameter by pressing the
3. Acting on
and
- d000=for operators with encoder;
- d001=for operators without encoder;
4. Confirm your choice by pressing the
to P029).
5 Selection 1 or 2 operators functioning
1. Scroll down the parameters with
lise P030;
2. Access the parameter by pressing the
3. Acting on
and
- d001=for a single motor operating;
- d002=for 2 motors operating;
4. Confirm your choice by pressing the
to P030).
6 Selection of direction of motion (only Type 00 and Type 03)
1. Scroll down the parameters with
you visualise P063;
2. Access the parameter by pressing the
3. Acting on
and
- d000=motor in standard position;
- d001=motor in inverted position;
4. Confirm your choice by pressing the
returns again to P063).
Warning: The parameter automatically reverses the
motors output open/close and any limit switch input
open/close.
7 how to adjust the limit switche
1. Scroll down the parameters untill you visualize P001;
2. confirm by pressing the
3. by pressing
(OPEN) and
leaf in the opening position and adjust the limit
switch cam so that it pushes the microswitch in that
point;
Repeat adjusting the closing limit switch.
4. Confirm by pressing the
P001).
WARNING If the Operator 2 is present, repeat the previous settings using P002.