5 ELECTRICAL CONNECTIONS
Execute the wiring following the directions of table 1 and diagrams.
WARNING To ensure an appropriate level of electrical safety always keep the 230V power supply cables apart (minimum 4mm in the
open or 1 mm through insulation) from low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary circuits
power supply), and fasten the latter with appropriate clamps near the terminal boards.
WARNING Connect to the power supply 230 V ~± 10% 50 Hz through a multi pole switch or a different device that can ensure multi pole
disconnection from the power supply, with a contact opening of 3 mm.
WARNING To connect the encoder to the control panel, use only a dedicated cable 3x0,22mm
3-4
22 V ~ transformer power supply input
5-6
24 V
7-8
Operator 1 output
9
Connection of motors metallic parts
10-11
Operator 2 output (if present)
24 V
12-13
P052>1)
14 (-)
14-15
15 (+)
16-17
24 V
18
Input 6
19 - Com
20
Input 5
21 - Com
22
Input 4
23 - Com
24
Input 3
25 - Com
26
Input 2
27 - Com
28
Input 1
29 - Com
Aerial signal input
30
31
Ground aerial input
32 (+)
32-33
33 (-)
1 (-)
1-2
2 (+)
Encoder selection Jumper:
J5
J9
•A position = operators with encoder (remind to set P029=0)
B
A
B
A
•B position = operators without encoder (remind to set P029=1)
30
Table 1 "terminal board connections"
battery power supply or photovoltaic accumulator Green Energy input (follow carefully polarity indications).
max 15 W output for open gate fix warning light (if P052=0), flashing (if P052=1) or courtesy light (if
"Boost" output for electric-lock, max 1 x art. 110 (if P062=0), 24V pulse output, max 5W (if P062=1), step
by step (if P062=2), electro-brake output for not self-locking operators (if P062=3), output for electric-lock
power supply via external relay (if P062=4), output for electro-magnets power supply for barriers (ifP062=5)
or temporized output (if P062>5).
Flashing light output max 15W art. Lumy/24A/S
TYPE 00
TYPE 01
(FCC 1)
(STOP)
N.C.
N.C.
(FCA 1)
(PHOTO 2)
N.C.
N.C.
( PHOTO 1)
(PHOTO 1)
N.C.
N.C.
(SAFETY)
(SAFETY)
N.C.
N.C.
(PEDESTRIAN)
(PEDESTRIAN)
N.O.
N.O.
(START)
(START)
N.O.
N.O.
24 V
power supply output for auxiliary devices
Stabilized 24 V
power supply output for tested safety devices
TYPE 02
If unused, short circuit
(NONE)
N.O.
(NONE)
N.O.
(STOP)
N.C.
(SAFETY)
N.C.
(PHOTO 1)
N.C.
(START)
N.O.
.
2
TYPE 03
(NONE)
N.O.
(NONE)
N.O.
(NONE)
N.O.
(NONE)
N.O.
(PHOTO 1)
N.C.
(START)
N.O.
(AUX + ST)
max 200mA
=

Publicité