ENGLISH
Principle
The HS-FE 150 and HS-FE 500 halogen floodlights with wireless receiver can receive wireless signals from
as many as eight Steinel transmitters with different addresses for switching the light "ON". The wireless
receiver only responds to transmitters that have first been assigned to it. For further information on setting
transmitters and receivers, please refer to the instructions of the IMPULSER system.
Safety warnings
Disconnect the power supply before attempting any work on the unit!
During installation, the electrical wiring you are connecting must be dead. Therefore, switch off the
power first and use a voltage tester to make sure the wiring is off circuit.
Installing these lights involves work on the mains voltage supply; this work must therefore be carried
out professionally in accordance with national wiring regulations and electrical operating conditions
( D - VDE 0100, A -ÖVE/ÖNORM E 8001-1,
-SEV 1000)
Do not install the unit on normally flammable surfaces.
The halogen floodlight must not be directed at the wall it is mounted on.
The light must be set to a horizontal position (± 15°).
Suitable for outdoor and indoor use (inndoor max. 25°C as no draft air).
The floodlight must be mounted in such a way that when it is set at any possible angle a
minimum distance of 1 metre is guaranteed between the light and the surface it shines on.
Halogen floodlights are only intended for wall mounting and not for ceiling mounting. They must be
installed at least 1 m from the ceiling.
If the glass cover breaks, always fit a new one before continuing use. Only
replace with special tempered glass in a thickness of 5 mm (HS-FE 150: 4 mm).
To avoid inflammation of the skin and eyes, do not expose yourself for any length of time to the halogen
floodlight if it is being operated at a voltage of 10 % above the specified voltage rating.
The floodlight housing heats up to a very high temperature while it is switched "ON". Only adjust the
angle of the floodlight once it has cooled down.
Only use genuine replacement parts
Do not dismantle the light yourself. It must only be repaired by a specialist workshop.
a
a
Installation
1
10
The mains supply lead is a 3-core cable.
Projected floodlight area:
L = phase conductor (usually black or brown )
N = neutral conductor (usually blue)
HS-FE 150: approx. 240 cm
HS-FE 500: approx. 448 cm
PE = protective-earth conductor (green/yellow)
Important: Getting the cable connections crossed will produce a short circuit in the unit or in your fuse
box. In this case, you must identify the individual cables and re-connect them. A mains switch for switching
the light "ON" and "OFF" can of course be installed in the mains lead.
Concealed wiring a , a / Surface wiring a , a
5
7
5a
7a
Underneath the mounting plate you will find two lugs for surface wiring. Break off one of the two lugs. Use
the sealing plug to close off the cable opening in the mounting plate. Pierce the sealing plug and feed the
cable through. Once the cable has been pushed through, you can screw the mounting plate to the moun-
ting surface and complete the connection.
Troubleshooting
(Fault / Cause
Remedy)
No voltage / Fuse faulty or not switched "ON", line broken
New fuse or turn "ON" mains power switch,
check wiring with voltage tester / Short circuit
Check connections.
Declaration of conformity
This product complies with Low Voltage Directive 06/95/EC, EMC Directive 04/108/EC and RoHS Directive
02/95/EC.
Functional Warranty
This Steinel product has been manufactured with utmost care, tested for proper operation and safety and
then subjected to random sample inspection. STEINEL guarantees that it is in perfect condition and proper
working order. The warranty period is 36 months and starts on the date of sale to the consumer. We will
remedy defects caused by material flaws or manufacturing faults. The warranty will be met by repair or
replacement of defective parts at our own discretion. The warranty does not cover damage to wear parts or
damage and defects caused by improper treatment, maintenance or the use of non-genuine parts. Further
consequential damage to other objects is excluded. Claims under the warranty will only be accepted if the
unit is sent fully assembled and well packed with a brief description of the fault, a receipt or invoice (date
of purchase and dealer's stamp) to the appropriate Service Centre.
Service:
Our Customer Service Department will repair faults not covered by warranty or after the warranty period.
Please send the product well packed to your nearest Service Centre.