Notice SANIWALL PRO Traduction_1:Mise en page 1
12
POSSIBLE CORRECTIVE MEASURES
Some problems with macerator functionality have
minor causes which you can rectify yourself.
Please refer to the table below in order to diagnose
and resolve your problems.
THE UNIT MUST ONLY BE OPENED BY AN APPROVED
SERVICE ENGINEER
THE MACERATOR SHOULD ALWAYS BE
DISCONNECTED FROM THE POWER SUPPLY
PROBLEM
• The unit stops
abnormally
• The unit starts itself up
intermittently
• The motor is juddering
and the water in the
bowl is going down
very slowly
• The motor is operating
normally but no longer
stops or runs for a long
time
• The motor no longer
activates
• The motor is running
with a rattling noise
or hums without
running
23/09/2008
SOLUTION
PROBABLE CAUSE
• Remove the plug.
• The unit has been
Wait an hour, then
running for too long
plug back in
(thermal cut-out)
• Defective control
• Otherwise, call an ap
system
proved service
engineer
• Check the installation
• The connected
sanitary appliances
upstream
are leaking
• Clean or replace the
• The non-return valve
non-return valve
is leaking
• The vent on the cover
• Clear the vent
is clogged up
• The height or length of
• Check the installation
drainage pipework is over
the specification or there
• Otherwise, call an
are too many elbows
approved service
(reducing flow)
engineer
• The pump chamber is
blocked
• Electrical power
• Connect the unit to the
supply is not active
electricity
• Defective plug
• Defective motor or
• Otherwise, call an
control system
approved service
engineer
• Remove the foreign
• Foreign object
object
blocking motor
• Defective motor or
• Otherwise, call an
control system
approved service
engineer
12:25
Page 20
13
REMOVAL
DISCONNECT FROM THE POWER SUPPLY BE-
FORE PROCEEDING
HOW TO CHECK THE MACERATOR
1-
DISCONNECT THE ELECTRICAL POWER SUPPLY
Turn off the toilet cistern tap. Bail out as much
water as possible from the toilet bowl siphon.
2 - Remove the toilet bowl.
3 - Remove the casing and the hatch to access the
removable frame .
n
4 - If a foreign body is preventing rotation, try to
remove it through the hole of the toilet inlet seal
using a screwdriver or a piece of flexible wire (first,
remove the discharge sleeve
WARNING!
Never try to reach in with your hand to release
the cutters (extremely sharp blades).
5 - If the non-return valve in the elbow
remove the elbow from the soil pipe
it (if needs be, change the flap
valve which unlocks by turning) if necessary.
Information only for approved service engineers:
- Take off the toilet bowl
- Disconnect the plumbing and electrical connections
- Unscrew the 4 bolts
O
- Pull the removable frame
- Unscrew the half-clamp
- Remove the macerator for repair or exchange
Once maintenance is complete, carry out the above
steps in reverse order.
14
GUARANTEE
is guaranteed for 2 years subject to
SANIWALL
Pro
®
correct installation and usage as described in these
instructions.
Zj
l
).
Zf
is clogged,
Zg
, and clean
Zf3
by undoing the
n
m