Preparing The Frame - SFA SANIWALL Pro Notice De Montage Et De Maintenance

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Notice SANIWALL PRO Traduction_1:Mise en page 1
NOTICE
SANIWALL
Pro is a wall unit with integrated
®
macerator specially designed for the installation of all
types of wall-hung toilet, shower and washbasin.
SANIWALL
Pro is designed for domestic use only.
®
Installed and maintained correctly, SANIWALL
will deliver a high level of performance, safety and
reliability.
Please pay particular attention to the following:
possible danger to personnel,
warning of potential electrical hazard,
"WARNING" A general warning that failure to
follow instructions could result in poor functioning
of the equipment.
Please contact our customer services for any
additional information.
2
LIST OF SUPPLIED PARTS
(fig.1 and fig.2)
3
DIMENSIONS (fig.3)
I
- Depth of frame = Between 200 and 245mm
II
- Thickness of casing = Between 16 and 100mm
III
- Height = Adjustable to between 1080 and 1280mm
IV
- Bowl height = 400 mm min ( finished floor )
V
- Max. thickness of finished floor = 185 mm
VI
- Height between floor and centre of macerator
discharge outlet = 220 mm mini
4
SANIWALL® Pro MACERATOR :
AREA OF USE AND TECHNICAL DATA
Area of use
Type
Maximum vertical discharge
Voltage
Frequency
Maximum absorbed power
Maximum absorbed current
Appliance class
Protection index
Net weight
WARNING: This equipment should not be used for
purposes other than those described in these
instructions.
5
PERFORMANCE CURVE (fig.5)
6
COMBINATIONS OF HEIGHT AND LENGTH
OF THE DISCHARGE PIPE (fig.6)
23/09/2008
Pro
®
Discharge of toilet waste
Discharge of washbasin waste
Discharge of shower waste
P 30
5m
220-240 V
50 Hz
400 W
1.8 A
I
IP44
5.6 KG
12:25
Page 16
INSTALLATION (figs. 7.1 to 7.6)
7
SANIWALL
is designed to be flush-mounted.
Pro
®
Installation should only be attempted by qualified
persons.
The macerator must be located in the same room as
the toilet and any other sanitary installations that may
also be connected.
The equipment must be easily accessible for checking
and maintenance purposes.
7.1

PREPARING THE FRAME

7.1.a
FITTING THE TOILET BOWL ANCHOR RODS
AND FIXING TO THE WALL
1 - WARNING: This frame should be fitted on a load
bearing wall if the floor structure is lightweight or
on a partition wall if the floor slab is suitable (NF
safety test: 400kg for wall-hung bowl). For
packaging purposes, the feet are folded inwards.
To reposition them correctly, they should be turned
outwards by a quarter turn.
2 - Measure the centre-to-centre distance (A)
between the bowl anchoring holes: there are only
2 possible measurements: (Ka = 230 mm ) and
(Kb = 180 mm).
Insert the rods
into the holes of the frame, as
K
per the centre-to-centre distance and fix them in
place using the nuts.
3 - Place the frame in position.
4 - Place the wall fixing lugs
fix them to the frame using the nuts, after having
checked that the frame is vertical
5 - Using a hacksaw, cut off any excess threaded rod
from the fixing lugs.
7.1.b
ADJUSTING THE HEIGHT OF THE FRAME
1 - Place the frame in its desired position.
2 - Unscrew the 4 set screws
3 - Adjust the height of the feet so that the front of the
bowl is 400mm from the finished floor.
4 - Check that the frame is horizontally level and
retighten the 4 set screws
7.1.c
PREPARING FIXING
1 - Mark out your drill points
(2 on the wall and 6 on the floor).
2 - Move the frame away and, using a 10mm bit, drill
2 holes (min. depth 70mm) in the wall.
Use an 8mm bit to drill 6 holes (min. depth 65mm)
in the floor.
3 - Insert the dowels
q
4 - Reposition the frame and move on to connecting
the SANIWALL
Pro
®
y
against the wall and
s
.
s
.
x
and
into the holes.
macerator.

Publicité

Table des Matières
loading

Table des Matières