Unit Description; Unit Installation - Hayward AQUARITE FLO ADVANCED Guide De L'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
2018
From
3 g salt/l
Water treatment system and controller for swimming pools.
Water treatment: Chlorine is produced by electrolysis of salt water, using salt water of low salinity. Production of
sodium hypochlorite (liquid chlorine) in the electrolysis cell is achieved with a minimum of 3g salt per litre. The chlorine
combats and eliminates bacteria, viruses and pathogenic agents, and oxidizes organic matter present in the water. The
used sodium hypochlorite reconverts into salt after a few hours. The system centralises control of all pool equipment,
optimising interactions between the various installations.
254 mm
ELECTRONIC BOX
Page 3 of 12
OWNER'S MANUAL
Upgrade
Worldwide
possible
remote control

1. UNIT DESCRIPTION

A
Main connection 230 V - 50 Hz
298 mm
A
Cell connection
B
B
Options connections
C
C
pH and Rx connection
D
D
ON/OFF switch
E
133 mm
Weight: 5.8 kg

2. UNIT INSTALLATION

A
Filtration pump timer*
B
Silex / glass / diatom filter
C
Recirculation pump
1
Electronic box
2
Electrolysis cell (always vertical)
3
pH probe (optional)
4
Rx probe (optional)
5
Temperature probe (optional)
6
WiFi module (optional)
7
Acid dosing pump (optional)
8
Acid injector (optional)
9
Hydrochloric acid container (not supplied)
USE ONLY GENUINE REPLACEMENT PARTS
AquaRite Flo Advanced
WiFi and
Self-cleaning
MODBUS
Øint
63 mm
Øext
63 mm
CELL
Use of a 25 A time delay circuit breaker is recommended
for AQR FLO ADVANCED devices. Where the power
supply is shared with other devices, please consult a
technician for correct sizing of your installation.
Product
8 Gr
16 Gr
22 Gr
33 Gr
50 Gr
EN
Sea water
Electrolysis cell
A
Connection to unit
B
Cell housing
C
Flow/gas detector (internal)
D
Electricity consumption
Maximum
g Cl 2 /h
Consumption
80 W
130 W
145 W
165 W
210 W
* Filtration control by external timer
Filtration mode:
"Manual / ON"
* Filtration control by internal timer
Filtration mode:
See section on Filtration
8
16
22
33
50
Rev. A

Publicité

Table des Matières
loading

Table des Matières