Masquer les pouces Voir aussi pour 5335:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Isolation
Galvanic isolators for analogue and digital
signals as well as HART
®
signals. A wide product range
with both loop-powered and universal isolators featuring
linearisation, inversion, and scaling of output signals.
Displays
Programmable displays with a wide se-
lection of inputs and outputs for display of temperature,
volume, weight, etc. Feature linearisation, scaling, and
difference measurement functions for programming via
PReset software.
Ex barriers
Interfaces for analogue and digital signals
as well as HART
®
signals between sensors / I/P convert-
ers / frequency signals and control systems in Ex zone 0,
1 & 2. Feature options such as mathematical functions
and 2 wire transmitter interfaces.
Temperature
A wide selection of transmitters for DIN
form B mounting and DIN rail modules with analogue
and digital bus communication ranging from application-
specifi c to universal transmitters.
Backplane
Flexible motherboard solutions for sys-
tem 5000 modules. Our backplane range features fl exible
8 and 16 module solutions with confi guration via PReplan
8470 – a PC program with drop-down menus.
5 3 3 5
2 - W i r e T r a n s m i t t e r
®
w i t h H A R T
P r o t o c o l
N o . 5 3 3 5 V 1 0 9 - I N ( 0 6 0 4 )
F r o m s e r . n o . 0 4 0 9 0 9 0 0 1
S I G N A L S T H E B E S T
Side 1
DK
Page 15
UK
Page 29
FR
Seite 43
DE

Publicité

Table des Matières
loading

Sommaire des Matières pour PR electronics 5335

  • Page 1 Isolation Galvanic isolators for analogue and digital signals as well as HART ® signals. A wide product range with both loop-powered and universal isolators featuring linearisation, inversion, and scaling of output signals. Displays Programmable displays with a wide se- lection of inputs and outputs for display of temperature, volume, weight, etc.
  • Page 2: Table Des Matières

    2-TRÅDS TRANSMITTER ® MED HART PROTOKOL PRetop 5335 Indholdsfortegnelse Sikkerhedsinstruktion ............Overensstemmelseserklæring ..........Anvendelse ................. Teknisk karakteristik ............Montage / installation ............Applikationer ..............Bestillingsskema ..............Elektriske specifikationer ........... Tilslutninger ................ 10 Blokdiagram ............... 11 Programmering ..............12 Forbindelse af transmittere i multidrop ......14 Mekaniske specifikationer ..........
  • Page 3: Sikkerhedsinstruktion

    OVERENSSTEMMELSESERKLÆRING Sikkerhedsinstruktion Som producent erklærer Ex-installation: PR electronics A/S Lerbakken 10 For sikker installation af 5335B, C og D i eksplosionsfarligt område skal føl- DK-8410 Rønde gende overholdes. Installation må kun foretages af kvalificeret personale, der er bekendt med de nationale og internationale love, direktiver og standarder, hermed at følgende produkt:...
  • Page 4: Anvendelse

    • Følerfejlsdetektering iht. retningslinierne i NAMUR NE 89. Montage / installation: • Kan monteres i DIN form B følerhoved. I ikke-eksplosionsfarlige områder kan 5335 monteres på en DIN-skinne med et specielt beslag. • NB: Som Ex-barriere for 5335B, C og D anbefaler vi 5106B.
  • Page 5: Elektriske Specifikationer

    Basisværdier Basis- Temperatur- Indgangstype nøjagtighed koefficient ≤ ±0,1°C ≤ ±0,005°C/°C Pt100 og Pt1000 ≤ ±0,2°C ≤ ±0,005°C/°C Ni100 ≤ ±0,1 Ω ≤ ±5 mΩ/°C Lin. R ≤ ±10 µV ≤ ±0,5 µV/°C Volt TC-type: ≤ ±0,5°C ≤ ±0,025°C/°C E, J, K, L, N, T, U TC-type: ≤...
  • Page 6 Følerfejlsdetektering ........Ja Ex- / I.S.-data: Kortslutningsdetektering ......Hvis 0% > 30 Ω Signaludgang / forsyning, terminal 1 til 2: TC-indgang: ..............: 30 VDC ..............: 120 mADC Min. Max. Min..............: 0,84 W Type temperatur temperatur span Norm ..............
  • Page 7: Tilslutninger

    Tilslutninger: Indgang: RTD, 2-leder RTD, 3-leder RTD, 4-leder TC, intern CJC TC, ekstern CJC Modstand, 2-leder Modstand, 3-leder TC, differens TC, differens RTD, differens eller middel, eller middel, Modstand, 4-leder eller middel med intern CJC med ekstern CJC mV, differens Udgang: eller middel 2-trådsinstallation...
  • Page 8: Programmering

    Programmering: Ved programmering henvises til tegningen nedenfor og hjælpefunktionen i PRetop 5335 kan konfigureres på 3 måder: PReset programmet. 1 Med PR electronics A/S’ kommunikationsinterface Loop Link og PReset PC konfigurationssoftware. ® 2. Med HART modem og PReset PC konfigurationssoftware.
  • Page 9: Forbindelse Af Transmittere I Multidrop

    2-WIRE TRANSMITTER ® WITH HART PROTOCOL ® HART kommunikatoren eller PC-modem kan tilsluttes over punkterne AB eller PRetop 5335 CONTENTS Safety instructions .............. 16 Declaration of Conformity ..........17 Application ................. 18 Technical characteristics ............ 18 Mounting / installation ............18 ®...
  • Page 10: Safety Instructions

    DECLARATION OF CONFORMITY Ex / I.S. installation: As manufacturer PR electronics A/S For a safe installation of 5335B, C and D in hazardous area the following must Lerbakken 10 be ob served. The module must only be installed by qualified personnel who DK-8410 Rønde...
  • Page 11: Application

    • Sensor error detection according to the guidelines in NAMUR NE 89. Mounting / installation: • For DIN form B sensor head mounting. In non-hazardous areas the 5335 can be mounted on a DIN rail with a special fitting. • NB: As Ex barrier for 5335B, C and D we recommend 5106B.
  • Page 12: Electrical Specifications

    Basic values Basic Temperature Input type accuracy coefficient ≤ ±0.1°C ≤ ±0.005°C/°C Pt100 and Pt1000 ≤ ±0.2°C ≤ ±0.005°C/°C Ni100 ≤ ±0.1 Ω ≤ ±5 mΩ/°C Lin. R ≤ ±10 µV ≤ ±0.5 µV/°C Volt TC type: ≤ ±0.5°C ≤ ±0.025°C/°C E, J, K, L, N, T, U TC type: ≤...
  • Page 13 Sensor error detection ........ Yes Ex / I.S. data: Short circuit detection ......... If 0% > 30 Ω Signal output / supply, terminal 1 to 2: TC input: ..............: 30 VDC ..............: 120 mADC Min. Max. Min..............: 0.84 W Type temperature temperature...
  • Page 14: Connections

    Connections: Input: RTD, 2-wire RTD, 3-wire RTD, 4-wire TC, internal CJC TC, external CJC Resistance, 2-wire Resistance, 3-wire TC, difference TC, difference RTD, difference or average, or average, Resistance, 4-wire or average with internal CJC with external CJC mV, difference Output: or average 2-wire installation...
  • Page 15: Programming

    For programming please refer to the drawing below. To gain access to product- ® specific commands, the HART communicator must be loaded with the ® PR electronics A/S DDL driver. This can be ordered either at the HART Commu nica tion Foundation or at PR electronics A/S.
  • Page 16: Connection Of Transmitters In Multidrop Mode

    TRANSMETTEUR 2-FILS ® AVEC PROTOCOLE HART ® The HART communicator or a PC modem can be connected accross AB or PRetop 5335 SOMMAIRE Consignes de sécurité ............30 Declaration de conformité ..........31 Application ................. 32 Caractéristiques techniques ..........32 Montage / installation ............
  • Page 17: Consignes De Sécurité

    : Type : 5335 L’année de production ressort des deux premiers chiffres du numéro de série. ®...
  • Page 18: Transmetteur 2-Fils Avec Protocole Hart

    • Détection de rupture sonde selon les recommandations NAMUR NE 89. Montage / installation : • Pour tête de sonde DIN B. En zone non-dangereuse le 5335 peut être monté sur rail DIN avec un support spécifique. • N.B. : Comme barrière S.I. pour le 5335B, C et D nous recommandons le PR5106B.
  • Page 19: Spécifications Électriques

    Valeurs de base Type Précision Coefficient d’entrée de base de température ≤ ±0,1°C ≤ ±0,005°C/°C Pt100 et Pt1000 ≤ ±0,2°C ≤ ±0,005°C/°C Ni100 ≤ ±0,1 Ω ≤ ±5 mΩ/°C R. Lin. ≤ ±10 µV ≤ ±0,5 µV/°C Volt Type TC : ≤...
  • Page 20 Détection de rupture sonde ......Oui Caractéristiques S.I. : Détection de court-circuit ......Si 0% > 30 Ω Sortie signal / alimentation, borne 1 à 2: Entrée TC : ..............: 30 Vcc ..............: 120 mAcc Température Température Plage ..............
  • Page 21: Connexions

    Connexions : Entrée : RTD, 2-fils RTD, 3-fils RTD, 4-fils TC, CSF interne TC, CSF externe Résistance, 2-fils Résistance, 3-fils TC, différence TC, différence RTD, différence ou moyen ou moyen Résistance, 4-fils ou moyen avec CSF interne avec CSF externe mV, différence Sortie : ou moyen...
  • Page 22: Programmation

    Pour le raccordement veuillez vous reporter au schéma ci-dessous. Pour avoir ® accès à tous les paramètres, le communicateur HART doit être chargé avec le DDL spécifique du PR electronics A/S. Ce DDL peut être commandé chez ® PR electronics A/S ou chez la Fondation HART...
  • Page 23: Raccordement Des Transmetteurs En Multi-Addressage

    MIT HART PROTOKOLL ® Le communicateur HART ou le modem peuvent être connectés sur les points AB ou sur les points BC. PRetop 5335 Inhaltsverzeichnis Sicherheitsinstruktion ............44 Konformitätserklärung ............45 Verwendung ................ 46 Technische Merkmale ............46 Montage / Installation ............46 Anwendungen ..............
  • Page 24: Sicherheitsinstruktion

    Sicherheitsinstruktion KONFORMITÄTSERKLÄRUNG Ex-Installation: Als Hersteller bescheinigt PR electronics A/S Für sichere Installation von 5335B in explosionsgefährdeter Umgebung muss Lerbakken 10 folgendes beobachtet werden. Die Installation muss nur von qualifizierten DK-8410 Rønde Personen, die mit den nationalen und internationalen Gesetze, Direktiven und Standards des Gebiets bekannt sind, vorgenommen werden.
  • Page 25: Verwendung

    • Fühlerfehlererkennung in Übereinstimmung mit der Richtlinien der NAMUR NE 89. Montage / Installation: • Für DIN Form B Sensorkopf Montage. Im sicheren Bereich kann der 5335 auf einer DIN- Schiene mittels einer spezieller Armatur montiert werden. • NB: Als Ex-Sicherheitsbarriere für 5335B, C und D empfehlen wir 5106B.
  • Page 26: Elektrische Daten

    Grundwerte Grund- Temperatur- Eingangsart Genauigkeit koeffizient ≤ ±0,1°C ≤ ±0,005°C/°C Pt100 und Pt1000 ≤ ±0,2°C ≤ ±0,005°C/°C Ni100 ≤ ±0,1 Ω ≤ ±5 mΩ/°C Lin. R ≤ ±10 µV ≤ ±0,5 µV/°C Volt TE-Typ: ≤ ±0,5°C ≤ ±0,025°C/°C E, J, K, L, N, T, U TE-Typ: ≤...
  • Page 27 Fühlerfehlererkennung ......... Ja Ex- / I.S.-Daten: Kurzschlusserkennung ........ Falls 0% > 30 Ω Signalausgang / Versorgung, Klemmen 1 bis 2: TE-Eingang: ..............: 30 VDC ..............: 120 mADC Min. Max. Min..............: 0,84 W Temperatur Temperatur Spanne Norm ..............
  • Page 28: Anschlüsse

    Anschlüsse: Eingang: WTH, 2-Leiter WTH, 3-Leiter WTH, 4-Leiter TE, interne CJC TE, externe CJC Widerst., 2-Leiter Widerst., 3-Leiter TE, Differenz TE, Differenz WTH, Differenz oder Mittel, oder Mittel, Widerst., 4-Leiter oder Mittel mit interner CJC mit externer CJC mV, Differenz Ausgang: oder Mittel 2-Draht-Installation...
  • Page 29: Programmierung

    ® 2: HART Modem: Programmierung: Bezüglich Programmierung verweisen wir auf die nachfolgende Zeichnung und PRetop 5335 kann in 3 verschiedener Weise programmiert werden: die “Hilfe”-Funktion im PReset-Programm. 1. Mittels PR electronics A/S’ Kommunikationsschnittstelle Loop Link und PReset PC Programmierungssoftware. ®...
  • Page 30: Parallelanschluss Von Signalgebern (Multidrop)

    Parallelanschluss von Signalgebern (Multidrop): APPENDIX ® Ein HART Datenaustauschgerät oder ein PC-Modem kann über die Punkte AB oder BC angeschlossen werden. Im Ausgang können bis zu 15 Signalgeber für eine digitale Kommunikation über Zweileiter parallel geschaltet werden. Jeder Signalgeber wird mit einer unverwechselbaren Nummer von 1 bis 15 FM Installation Drawing No.
  • Page 31 The entity concept. Installation Drawing 5300Q502. The Transmitter must be installed according to National Electrical Code (ANSI-NFPA 70). Model 5331C,5331D, 5333C and 5333D When installed in Class II locations the Transmitter shall be installed in an enclosure Non Hazardous Location Hazardous (Classified) Location with a specified ingress protections of IP6X according to IEC60529 and Dust-tight conduit seals must be used.
  • Page 32 CSA Installation Drawing 533XQC03. 5331D, 5333D and 5335D transmitters are intrinsically safe in Zone 0 Group IIC 2. Connection with power supply and barrier built into receiver. or Class I, Division1, Group A,B,C,D when installed according to Installation Output: Standard 4 - 20 mA loop Drawing.
  • Page 33 Subsidiaries PR electronics A/S tilbyder et bredt program af analoge og digi- France tale signalbehandlingsmoduler til industriel automation. Vores PR electronics Sarl Zac du Chêne, Activillage sales@prelectronics.fr kompetenceområder omfatter: Isolation, Displays, Ex-barrierer, 2, allée des Sorbiers, tel. +33 (0) 4 72 14 06 07 Temperatur samt Universal-moduler.

Table des Matières