Masquer les pouces Voir aussi pour 5331:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Displays
Programmable displays with a wide se-
lection of inputs and outputs for display of temperature,
volume and weight, etc. Feature linearisation, scaling,
and difference measurement functions for programming
via PReset software.
Ex barriers
Interfaces
for
analogue
®
signals as well as HART
signals between sensors / I/P
converters / frequency signals and control systems in Ex
zone 0, 1 & 2 and for some modules in zone 20, 21 & 22.
Isolation
Galvanic isolators for analogue and digital
signals as well as HART
®
signals. A wide product range
with both loop-powered and universal isolators featuring
linearisation, inversion, and scaling of output signals.
Temperature
A wide selection of transmitters for DIN
form B mounting and DIN rail modules with analogue
and digital bus communication ranging from application-
specifi c to universal transmitters.
Universal
PC or front programmable modules with
universal options for input, output and supply. This range
offers a number of advanced features such as process
calibration, linearisation and auto-diagnosis.
and
digital
5 3 3 1
2 - W i r e P r o g r a m m a b l e
T r a n s m i t t e r
N o . 5 3 3 1 V 1 1 0 - I N ( 0 6 1 2 )
F r o m s e r . n o . 0 1 0 4 5 5 0 0 1
S I G N A L S T H E B E S T
Side 1
DK
Page 13
UK
Page 25
FR
Seite 37
DE

Publicité

Table des Matières
loading

Sommaire des Matières pour PR electronics 5331

  • Page 1 Displays Programmable displays with a wide se- lection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearisation, scaling, and difference measurement functions for programming via PReset software. Ex barriers Interfaces analogue digital ® signals as well as HART signals between sensors / I/P converters / frequency signals and control systems in Ex zone 0, 1 &...
  • Page 2: Table Des Matières

    2-TRÅDS PROGRAMMERBAR TRANSMITTER PRetop 5331 Indholdsfortegnelse Sikkerhedsinstruktion ............Overensstemmelseserklæring ..........Anvendelse ................. Teknisk karakteristik ............Montage / installation ............Applikationer ..............Bestillingsskema ..............Elektriske specifikationer ........... Tilslutninger ................ 10 Blokdiagram ............... 11 Programmering ..............12 Mekaniske specifikationer ..........12 Montering af følerledninger ..........12 Appendix: FM Installation Drawing No.
  • Page 3: Sikkerhedsinstruktion

    Sikkerhedsinstruktion OVERENSSTEMMELSESERKLÆRING Ex-installation: Som producent erklærer PR electronics A/S For sikker installation af 5331B, C og D i eksplosionsfarligt område skal føl- Lerbakken 10 gende overholdes. Installation må kun foretages af kvalificeret personale, der DK-8410 Rønde er bekendt med de nationale og internationale love, direktiver og standarder, der gælder for området.
  • Page 4: Anvendelse

    • Der er løbende sikkerhedscheck af gemte data. Montage / installation: • Kan monteres i DIN form B følerhoved. I ikke-eksplosionsfarlige områder kan 5331 monteres på en DIN-skinne med et specielt beslag. • NB: Som Ex-barriere for 5331B anbefaler vi 5104B, 5114B eller 5116B.
  • Page 5: Bestillingsskema

    Bestillingsskema: 5331 Basisværdier Basis Temperatur- Indgangstype nøjagtighed koefficient ≤ ±0,2°C ≤ ±0,01°C/°C Omgivelses- Galvanisk Type Version ≤ ±0,1 Ω ≤ ±10 mΩ/°C temperatur isolation Lin.R ≤ ±10 µV ≤ ±1 µV/°C Standard -40°C…+85°C : 3 1500 VAC : B Volt...
  • Page 6 Virkning af følerkabelmodstand Følerfejlsdetektering: (3- / 4-leder) ..........< 0,002 Ω/Ω Programmerbar ........... 3,5...23 mA Følerfejlsdetektering ........Ja NAMUR NE43 Upscale ....... 23 mA NAMUR NE43 Downscale ......3,5 mA TC-indgang: Ex- / I.S.-data: Min. Max. Min. U i ..............: 28 VDC Type temperatur temperatur...
  • Page 8: Programmering

    Programmering: 2-WIRE PROGRAMMABLE TRANSMITTER • Loop Link er et batteridrevet kommunikationsinterface, der er nødvendigt for programmering af PRetop 5331. PRetop 5331 • Ved programmering henvises til tegningen nedenfor og hjælpefunktionen i PReset programmet. • Loop Link må ikke benyttes til kommunikation med moduler installeret i Ex- område...
  • Page 9: Safety Instructions

    Safety instructions DECLARATION OF CONFORMITY Ex installation: As manufacturer PR electronics A/S For a safe installation of 5331B, C and D in hazardous area the following must Lerbakken 10 be observed. The module must only be installed by qualified personnel who DK-8410 Rønde...
  • Page 10: Application

    • Continuous check of vital stored data for safety reasons. Mounting / installation: • For DIN form B sensor head mounting. In non-hazardous areas the 5331 can be mounted on a DIN rail with a special fitting. • NB: As Ex barrier for 5331B we recommend 5401B, 5114B, or 5116B.
  • Page 11: Order

    Order: 5331 Basic values Basic Temperature Input type accuracy coefficient ≤ ±0.2°C ≤ ±0.01°C/°C Ambient Galvanic Type Version ≤ ±0.1 Ω ≤ ±10 mΩ/°C temperature isolation Lin.R ≤ ±10 µV ≤ ±1 µV/°C Standard -40°C…+85°C : 3 1500 VAC : B...
  • Page 12 TC input: Sensor error detection: Programmable ..........3.5...23 mA Min. Max. Min. Namur NE43 Upscale ........23 mA Type temperature temperature span Standard Namur NE43 Downscale ......3.5 mA +400°C +1820°C 200°C IEC584 Ex / I.S. data: -100°C +1000°C 50°C IEC584 U i ..............
  • Page 14: Programming

    Programming: TRANSMETTEUR 2-FILS UNIVERSEL (Pt100/TC) • Loop Link is a communications interface that is needed for programming PRetop 5331. PRetop 5331 • For programming please refer to the drawing below and the help functions in PReset. • Loop link is not approved for communication with modules installed in harzard-...
  • Page 15: Consigne De Sécurité

    : Type : 5331 L’année de production ressort des deux premiers chiffres du numéro de série. Nom : Transmetteur 2-fils universel Pour les conditions d’installation et les données de sécurité...
  • Page 16: Transmetteur 2-Fils Universel (Pt100/Tc)

    • Vérification continue des données sauvegardées. Montage / installation : • Pour tête de sonde DIN B. En zone non-dangereuse le 5331 peut être monté sur rail DIN avec un support spécifique. • N.B. : Comme barrière S.I. pour le 5331B nous recommandons le PR5104B,...
  • Page 17: Référence

    Référence : 5331 Valeurs de base Type Précision Coefficient d’entrée de base de température ≤ ±0,2°C ≤ ±0,01°C/°C Température Isolation Type Version ≤ ±0,1 Ω ≤ ±10 mΩ/°C ambiante galvanique R. Lin. ≤ ±10 µV ≤ ±1 µV/°C Standard -40°C…+85°C : 3...
  • Page 18 Entrée TC : Détection de rupture de sonde : Programmable ..........3,5...23 mA Température Température Plage NAMUR NE43 Haut d’échelle ..... 23 mA Type min. max. min. Standard NAMUR NE43 Bas d’échelle ....... 3,5 mA +400°C +1820°C 200°C IEC584 Caractéristiques S.I. : -100°C +1000°C 50°C...
  • Page 20: Programmation

    UNIVERSALMESSUMFORMER • Loop Link est un kit de programmation permettant de programmer le PRetop 5331. PRetop 5331 • Pour le raccordement du Loop Link, veuillez vous reporter au schéma ci- dessous et à l’aide en ligne du logiciel PReset. • Loop Link ne doit pas être utilisé pour communication avec des modules installés en zone dangereuse.
  • Page 21: Sicherheitsinstruktion

    Sicherheitsinstruktion KONFORMITÄTSERKLÄRUNG Ex-Installation: Als Hersteller bescheinigt PR electronics A/S Für sichere Installation von 5331B, C und D in explosionsgefährdeter Lerbakken 10 Umgebung muss folgendes beobachtet werden. Die Installation muss nur von DK-8410 Rønde qualifizierten Personen, die mit den nationalen und internationalen Gesetze, Direktiven und Standards des Gebiets bekannt sind, vorgenommen werden.
  • Page 22: Verwendung

    • Die gespeicherten Daten werden laufend kontrolliert. Montage / Installation: • Für DIN Form B Sensorkopf Montage. Im sicheren Bereich kann der 5331 auf einer DIN- Schiene mittels einer spezieller Armatur montiert werden. • NB: Als Ex-Sicherheitsbarriere für 5331B empfehlen wir 5104B, 5114B oder...
  • Page 23: Bestellangaben

    Bestellangaben: 5331 Grundwerte Grund- Temperatur- Eingangsart Genauigkeit koeffizient ≤ ±0,2°C ≤ ±0,01°C/°C Umgebungs- Galvanische Version ≤ ±0,1 Ω ≤ ±10 mΩ/°C Lin. R temperatur Trennung ≤ ±10 µV ≤ ±1 µV/°C Volt Standard -40°C…+85°C : 3 1500 VAC : B...
  • Page 24 Wirkung des Fühlerkabelwiederstandes Sensorfehlanzeige: (3- / 4-Leiter) ..........< 0,002 Ω/ Ω Programmierbar ......... 3,5...23 mA Fühlerfehlererkennung ......... Ja NAMUR NE43 aufsteuernd ......23 mA NAMUR NE43 zusteuernd ......3,5 mA TE-Eingang: Ex- / I.S.-Daten: U i ..............: 28 VDC Min.
  • Page 26: Programmierung

    Programmierung: APPENDIX • Loop Link ist eine batteriegespeiste Schnittstelle zur Programmierung des PRetop 5331. • Bezüglich Programmierung verweisen wir auf die nachfolgende Zeichnung und die “Hilfe”-Funktion im PReset-Programm. • Loop Link darf nicht zur kommunikation mit Modulen, die in Ex-gefährdeten Bereichen installiert sind, benutz werden.
  • Page 27 The entity concept. Installation Drawing 5300Q502. The Transmitter must be installed according to National Electrical Code (ANSI-NFPA 70). Model 5331C,5331D, 5333C and 5333D When installed in Class II locations the Transmitter shall be installed in an enclosure Non Hazardous Location Hazardous (Classified) Location with a specified ingress protections of IP6X according to IEC60529 and Dust-tight conduit seals must be used.
  • Page 28 CSA Installation Drawing 533XQC03. 5331D, 5333D and 5335D transmitters are intrinsically safe in Zone 0 Group IIC 2. Connection with power supply and barrier built into receiver. or Class I, Division1, Group A,B,C,D when installed according to Installation Output: Standard 4 - 20 mA loop Drawing.
  • Page 29 Subsidiaries PR electronics A/S tilbyder et bredt program af analoge og digi- France tale signalbehandlingsmoduler til industriel automation. Vores PR electronics Sarl Zac du Chêne, Activillage sales@prelectronics.fr kompetenceområder omfatter: Isolation, Displays, Ex-barrierer, 2, allée des Sorbiers, tel. +33 (0) 4 72 14 06 07 Temperatur samt Universal-moduler.

Ce manuel est également adapté pour:

Pretop 5331

Table des Matières