Page 1
5 3 3 4 T r a n s m e t t e u r 2 - f i l s u n i v e r s e l ( T C ) N o 5 3 3 4 V 1 1 0 - F R A p a rt ir du n o de sér ie 141365 001 CCOE...
Page 2
Revision Notes The following list provides notes concerning revisions of this document. Rev. ID Date Notes 13/45 IECEx and INMETRO approvals added 15/14 PESO/CCOE approval added GOST approval replaced with EAC approval 17/07 INMETRO installation drawings updated 1707...
• Vérification continue des données sauvegardées. Montage / installation • Pour tête de sonde DIN B. En zone non-dangereuse le 5334 peut être monté sur rail DIN avec le support PR type 8421. 5334V 11 0 -FR...
Valeurs de base Type Précision Coefficient d’entrée de base de température ≤ ±10 µV ≤ ±1 µV / °C Volt Type TC : E, J, K, L, N, T, U ≤ ±1°C ≤ ±0,05°C / °C Type TC : B, R, S, ≤...
Page 8
Compensation de soudure froide ...... < ±1,0°C Détection de rupture de sonde ......Oui Courant de sonde : Pendant la détection ......... Nom. 33 mA Si non ............... 0 mA Entrée tension : Gamme de mesure ........... -12...150 mV Plage de mesure min..........5 mV Résistance d’entrée ..........
PROGRAMMATION • Loop Link est un kit de programmation permettant de programmer le 5334. • Pour le raccordement du Loop Link, veuillez vous reporter au schéma ci-dessous et à l’aide en ligne du logiciel PReset. • Loop Link ne doit pas être utilisé pour communication avec des modules installés en zone dangereuse.
Dimensions mécaniques Montage des fils du capteur ø 6 mm 20.2 m m 33 mm ø 44 mm Les fils doivent être montés entre les plaques métalliques. 5334V 11 0 -FR...
5331QA02 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM Schéma d’installation ATEX Pour une installation sûre du 5331A3B ou du 5334A3B vous devez observer ce qui suit. Le module sera seulement installé par un personnel qualifié qui est informé des lois, des directives et des normes nationales et internationales qui s'appliquent à...
Page 15
5331QA01 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM Schéma d’installation ATEX Pour une installation sûre du 5331D ou 5334B vous devez observer ce qui suit. Le module sera seulement installé par un personnel qualifié qui est informé des lois, des directives et des normes nationales et internationales qui s'appliquent à...
Page 16
5331QA01 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM Notes d’installation L’isolation galvanique entre le circuit du capteur et le circuit d’entrée n’est pas infaillible. Cependant, l’isolation galvanique entre les circuits est capable de résister à une tension de test de 500 Vca pendant 1 minute. Dans les atmosphères potentiellement explosibles dû...
5331QI02 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM IECEx Installation drawing For safe installation of 5331A or 5334A the following must be observed. The module shall only be installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area.
Page 18
5331QI01 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM IECEx Installation drawing For safe installation of 5331D or 5334B the following must be observed. The module shall only be Installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area.
Page 19
5331QI01 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM Installation notes. The sensor circuit is not infallibly galvanic isolated from the input circuit. However, the galvanic isolation between the circuits is capable of withstanding a test voltage of 500Vac during 1 minute. In a potentially explosive gas atmosphere, the transmitter shall be mounted in a metal form B enclosure in order to provide a degree of protection of at least IP20 according to IEC60529.
Page 20
5331QB02 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM Desenho de Instalação INMETRO Para instalação segura do 5331A ou 5334A o seguinte deve ser observado. O modelo deve apenas ser instalado por pessoas qualificadas que são familiarizadas com as leis nacionais e internacionais, diretrizes e padrões que se aplicam a esta área.
Page 21
5331QB01 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM Desenho de Instalação INMETRO Para instalação segura do 5331D ou 5334B o seguinte deve ser observado. O modelo deve apenas ser instalado por pessoas qualificadas que são familiarizadas com as leis nacionais e internacionais, diretrizes e padrões que se aplicam a esta área.
Page 22
5331QB01 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM Notas de instalação O circuito do sensor não é isolado galvanicamente do circuito de entrada de forma infalível. Contudo, a isolação galvânica entre os circuitos é capaz de resistir a um ensaio de tensão de 500Vac durante 1 minuto.
Page 23
Displays Programmable displays with a wide selection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearization, scaling, and difference measurement functions for programming via PReset software. Ex interfaces Interfaces for analog and digital signals as well as HART signals between sensors / I/P converters / frequency signals and control systems in Ex zone 0, 1 &...