26. DO NOT MODIFY THE COMPRESSOR.
Do not modify the compressor. Do not drill into, weld,
patch or modify the air tanks. Do not make adjustments
to the components that control tank pressure. Do not
make alterations to the factory operating pressure
settings. Do not operate at pressures or speeds in
excess of the manufacturer's recommendations.
Always contact the metabo HPT authorized service
center for any repairs. Unauthorized modifi cation may
not only impair the compressor performance but may
also result in accidents or injury to repair personnel
who do not have the required knowledge and technical
expertise to perform the repair operations correctly.
27. TURN OFF THE POWER SWITCH WHEN THE
COMPRESSOR IS NOT USED.
When the compressor is not used, turn off the power
switch, disconnect the plug from the power source
and open the drain cock to discharge the compressed
air from the air tank.
28. NEVER TOUCH HOT SURFACE.
To reduce the risk of burns, do not touch the delivery
pipe, check valve or pump.
These areas can remain hot for at least 45 minutes
after this compressor is shutdown.
Allow compressor to cool prior to servicing.
29. DO NOT DIRECT AIR STREAM AT BODY.
Risk of injury. Do not direct air stream at persons or
animals.
30. DRAIN TANK.
Risk of bursting. Water will condense in the air tank.
If not drained, water will corrode and weaken the air
tank causing a risk of air tank rupture.
Drain tank daily or after 4 hours of use. To drain the air
tank, open valves slowly and tilt compressor to empty
accumulated water.
Keep face and the other body parts away from outlet
of drain.
Use ANSI Z87.1 safety glasses with side shields when
draining as debris can be kicked up into face.
31. DO NOT STOP COMPRESSOR BY PULLING OUT
THE PLUG.
This could result in damage to the unit.
Use the power switch.
6
32. MAKE SURE THE COMPRESSOR OUTLET
PRESSURE IS SET LOWER THAN THE MAXIMUM
OPERATING PRESSURE OF THE TOOL.
Too much air pressure causes a hazardous risk of
bursting.
Check the manufacturer's maximum pressure rating
for air tools and accessories. The regulator outlet
pressure must never exceed the maximum pressure
rating.
33. THE SAFETY VALVE MUST WORK PROPERLY.
Risk of bursting. Before starting the compressor,
pull the ring on the safety valve to make sure that the
safety valve operates smoothly. If the safety valve
does not work properly, over-pressurization may
occur, causing air tank rupture or an explosion. Do not
use compressor if the safety valve is stuck or does
not operate smoothly. Have defective safety valve
replaced by a metabo HPT authorized service center.
34. USE OF THIS PRODUCT WILL EXPOSE YOU
TO CHEMICALS KNOWN TO THE STATE OF
CALIFORNIA.
Some dust created by this product contains chemicals
known to State of California to cause cancer, birth
defects or other reproductive harm. Some examples
of these chemicals are:
– compounds in fertilizers
– compounds in insecticides, herbicides and
pesticides
– arsenic and chromium from chemically treated
lumber
To reduce your exposure to these chemicals, wear
approved safety equipment such as dust masks
that are specially designed to fi lter out microscopic
particles. Use of this product will expose you to
chemicals known to the State of California to cause
cancer, birth defects and other reproductive harm.
Avoid inhaling vapors and dust, and wash hands after
using. This product contains chemicals, including
lead, known to the State of California to cause cancer,
and birth defects or other reproductive harm. Wash
hands after handling.
35. PROTECT MATERIAL LINES AND AIR LINES
FROM DAMAGE OR PUNCTURE.
Keep the hose and power cord away from sharp
objects, chemical spills, oil, solvents, and wet fl oors.
36. CHECK HOSES FOR WEAK OR WORN CONDITION
BEFORE EACH USE, MAKING CERTAIN ALL
CONNECTIONS ARE SECURE.
Do not use if a defect is found. Purchase a new hose
or notify an authorized service center for examination
or repair.