Filling the IV Bag

Use a syringe to inject fluid into IV bags, and fill to desired level.
Control flow of blood into arm and legs, via valves.
Connecting the SpO
The SpO
probe is made up of a light diode and light sensor. When
2
the beam between the diode and sensor is broken, the Patient Moni-
tor Application registers that the SpO
When the probe cable is connected to the Link Box, SpO
not be displayed until the probe is placed onto the simulator. If the
probe is not attached to the Link Box, SpO
automatically when selected by the user through the instructor panel
on the PC.

Connecting to the Link Box

Attach simulator cable to right lower side of simulator's torso and to
the connector marked "Simulator" on the back of the Link Box.
1. Connect serial cable to connector marked "PC" on the back of
the Link Box and to serial port on back of your computer.
2. Connect clear tubing from blood pressure cuff to the inlet
marked "BP cuff " on the back of the Link Box.
3. Connect the SpO
cable to the SpO
2
the Link Box.
4. Connect one end of the audio cable to the connector marked
"Audio input" on the back of the Link Box and one to the Pa-
tient Monitor, and the other end with the mini-jack plug into the
headphone outlet of your computer.
5. Plug the Link Box AC power cable into a power supply (110-240
V AC). If you are using the Portability Kit, attach to the 12 V DC
input according to the Portability Kit instructions.
6. Connect external speakers, if used, to connector marked "Ext.
speaker" on back of Link Box (external speakers not included).
SETUP
Probe
2
probe is connected.
2
will
2
will only be displayed
2
connector on the back of
2
12