5 Hook the front of the housing
onto the base plate at the top and
close. Tighten the screw on the
underneath of the housing.
Mounting SNG 850-...
6 Mount the line rectifier on the top
hat rail (distribution).
7 Surface mounting is possible with
accessory ZAP 9-0. (not included in
scope of supply)
Mounting AIB 150-...
8 Recommended mounting height
appr. 1.50 m/4.9 ft to centre device.
9 Open the device by pushing in
the locking lever and taking off the
front side.
10 When mounting directly on the
wall, fasten the base plate using
2 screws, paying attention that
the plate is the right way up (top
marking).
11 When mounting on a switch box,
use the screw openings in the centre
of the device, paying attention that
the plate is the right way up (top
marking).
12 Install in accordance with the
wiring diagram. The cores of the
installation cable must be stored
inside the free installation space in
the base plate.
13 Place the housing on the base
plate from above and close by
exerting a slight pressure.
With Plug+Play programming do not
close the housing until programming
is under way. Hook the housing into
the base plate from above and close
by exerting a slight pressure.
Dismantling
14 To remove the housing, push the
catch downwards. The pcb remains
in the top part of the housing.
Lettering
15 Open the nameplate from the
outside, for example using a flat
bladed screwdriver, and carefully
remove the inscription insert. To
insert the nameplate, lock into place
by exerting light pressure.
16 Info sign from the inside, e.g.
open using flat blade screwdriver
and remove inscription field. To
insert, clip in the info sign exerting a
slight pressure.
Installation
17 Connect in accordance with the
relevant circuit diagram.
18 Circuit diagram for
SET CAB 850-... extended with
one Vario door station
Range
SNG 850-... to door station
max. 100 m,
SNG 850-... to the most remote
indoor device max. 100 m, with
0.8 mm core diameter.
Terminal assignment CA 850-...
Ta, Tb
In-Home bus
Tö, Tö
Relay contact
door release
Terminal assignment AIB 150-...
Ta, Tb
In-Home bus
ERT
Storey call button
Terminal assignment SNG 850-...
L1, N
Power connection
Ta, Tb
In-Home bus
b, c
Power supply 12 V AC
Tö, Tö
Relay contact
door release
Li, Li
Relay contact light
Commissioning
Simple commissioning using
Plug+Play programming.
Upgrade capability
The Basic set can be extended with
the following components. The
overall extension of the Basic sets set
must not exceed 10 users, whereby
one door station supports two users.
• Audio indoor station Siedle Basic
AIB 150-...
• DoorCom Analog DCA 650-...
• Bus switching unit BSE 650-...
• Audio door station of the In-Home
bus system
Further system components may be
needed.
Specifications
CA 850-...:
Operating voltage: via In-Home bus
Contact type: contact 24 V, 2 A
Protection system: IP 54
Ambient temperature:
–20 °C to +55 °C
Dimensions (mm) W x H x D:
82 x 226 x 33
AIB 150-01:
Operating voltage: via In-Home bus
Dimensions (mm) W x H x D:
79 x 133 x 23
SNG 850-0:
Operating voltage:
230 V AC, +/-10 %, 50/60 Hz
Operating current: 200 mA
Output voltage: 27.5 V DC, 12 V AC
Output current: 0.5 A DC, 1 A AC
Fusing: Primary fuse 1 T 250 mA L,
secondary short circuit proof
Contact type:
2 n.o. contacts 24 V, 2 A
Protection system: IP 30
Ambient temperature:
0 °C to +40 °C
Horizontal pitch (HP): 9
Dimensions (mm) W x H x D:
162 x 89 x 60
15