Application
Siedle Basic audio set in bus tech-
nology with the functions calling,
speech and door release.
Number of integrated call buttons:
1, 2, 4
Each Basic set can be expanded with
selected door and indoor stations,
and enhanced with switching func-
tions and a telephony connection.
CA 850-... door station
performance features:
• Integrated door loudspeaker
• Adjustable voice volume
• Number of integrated call but-
tons: 1 (CA 850-1), 2 (CA 850-2),
4 (CA 850-3/4)
• Acoustic button acknowledgement
can be activated
• Backlit nameplates exchangeable
from the front
• Backlit info sign for house number,
logos, opening times, etc.
• For surface mounting with housing
front made of high-quality plastic
AIB 150-01 indoor station
performance features:
• Speech and call volume can be set
in five stages
• 11 call tones
• Call differentiation: Storey call,
2 door calls and internal call from
standard/deluxe indoor stations
• LED status display: Incoming calls,
active call, muting
• Door release/light function via the
bus line
• Manual door connection even
without a door call
• Parallel switching of max. 4 indoor
stations without internal speech
operation
• Handy 2-step mounting: Base plate
with terminals can be pre-installed,
toolless final assembly
14
SNG 850-0 set line rectifier
performance features:
• 10 bus addresses for supplying the
bus users
• Integrated door release and light
contact
• Programming: manual, Plug+Play
or via BPS 650-... (Windows
PC) with ZBVG 650-... and
PRI 602-... USB
Electrical voltage
• Mounting, installation and ser-
vicing work on electrical devices may
only be performed by a suitably
qualified electrician.
• Failure to observe this regulation
could result in the risk of serious
damage to health or fatal injury due
to electric shocks.
• Observe DIN EN 60065! In a
building installation, an all-pole
mains switch with a contact opening
of at least 3 mm must be provided.
The transformer must not be
exposed to water drops or sprayed
water! Ensure sufficient ventilation,
paying particular attention to ensure
that ventilation slots are not covered.
• For surface mounting, ensure that
"protection against direct contact"
with active parts is provided. For
details, consult VDE 0100/DIN 57100
part 410.
• When using stranded cores as
cable material, these must be fitted
with wire end ferrules without fail.
Electrostatic charging
As a result of electrostatic charging,
direct contact with the circuit board
can result in destruction of the
device. Direct contact with the circuit
board must therefore be avoided.
Scope of supply SET CAB 850-1 
• CA 850-1
• AIB 150-...
• SNG 850-...
• Siedle screwdriver
• This product information
Scope of supply SET CAB 850-2
• CA 850-2
• 2 x AIB 150-...
• SNG 850-...
• Siedle screwdriver
• This product information
Scope of supply SET CAB 850-3
• CA 850-4
• 3 x AIB 150-...
• SNG 850-...
• Siedle screwdriver
• This product information
Scope of supply SET CAB 850-4
• CA 850-4
• 4 x AIB 150-...
• SNG 850-...
• Siedle screwdriver
• This product information
Mounting CA 850...
1 Unscrew the front of the housing.
To do this, release the Siedle screw
on the underneath of the housing.
Hinge the front of the housing
forward.
2 Surface mounting the door sta-
tion. Recommended mounting
height appr. 1.50 m /4.9 ft. to centre
device. Please note: The cable is
inserted in the lower area of the
base plate!
3 Strip back the installation cable
close to the wall (appr. 10 mm)
and insert the cores into the base
plate. Fasten the base plate using 4
screws. Close the two openings at
the top using rubber stoppers. Install
in accordance with the terminal
diagram.
4 Depending on the installation
environment, it may be necessary
to change the door station speech
volume in order to permit clear
speech transmission.

Publicité