7
Technical data
7.1
Measuring range and accuracy
Measuring range
bar
0 bar to 0.25 bar relative pressure
0 bar to 0.4 bar relative pressure
0 bar to 0.6 bar relative pressure
0 bar to 1 bar relative pressure
0 bar to 1.6 bar relative pressure
0 bar to 2.5 bar relative pressure
0 bar to 4 bar relative pressure
0 bar to 6 bar relative pressure
0 bar to 10 bar relative pressure
0 bar to 16 bar relative pressure
0 bar to 25 bar relative pressure
0 bar to 40 bar relative pressure
0 bar to 60 bar relative pressure
0 bar to 100 bar relative pressure
0 bar to 160 bar relative pressure
0 bar to 250 bar relative pressure
0 bar to 400 bar relative pressure
0 bar to 600 bar relative pressure
-1 bar to 0 bar relative pressure
-1 bar to +0.6 bar relative pressure 0.3
-1 bar to +1.5 bar relative pressure 0.3
-1 bar to +3 bar relative pressure
-1 bar to +5 bar relative pressure
-1 bar to +9 bar relative pressure
-1 bar to +15 bar relative pressure
-1 bar to +24 bar relative pressure
0 bar to 0.6 bar absolute pressure
0 bar to 1 bar absolute pressure
0 bar to 1.6 bar absolute pressure
0 bar to 2.5 bar absolute pressure
0 bar to 4 bar absolute pressure
0 bar to 6 bar absolute pressure
0 bar to 10 bar absolute pressure
0 bar to 16 bar absolute pressure
0 bar to 25 bar absolute pressure
a
Linearity according to limit point setting
b
Reference conditions EN 61298-1
c
All pressure transmitters are vacuum proof.
d
Includes: linearity, hysteresis, repeatability, deviation of measuring range initial value and measuring span (MSP)
e
Includes: linearity, hysteresis, repeatability, deviation of measuring range initial value and measuring span (MSP),
thermal effect on measuring range start and measuring span (MSP)
a
Linearity
Accuracy at
d
20 °C
% MSP
% MSP
0.3
0.7
0.3
0.7
0.3
0.6
0.3
0.5
0.25
0.5
0.25
0.5
0.25
0.5
0.25
0.5
0.25
0.5
0.2
0.5
0.2
0.5
0.2
0.5
0.2
0.5
0.2
0.5
0.3
0.7
0.3
0.7
0.3
0.7
0.3
0.7
0.3
0.5
0.5
0.5
0.3
0.5
0.25
0.5
0.25
0.5
0.25
0.5
0.2
0.5
0.3
0.6
0.3
0.5
0.25
0.5
0.25
0.5
0.25
0.5
0.25
0.5
0.25
0.5
0.2
0.5
0.2
0.5
7 Technical data
Long-term
e
stability
-20 to +80 °C
% MSP
% MSP
per year
2.0
≤ 0.2
1.8
1.8
1.3
1.3
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.3
1.3
1.2
1.2
1.2
1.0
1.0
1.0
1.8
1.3
1.3
1.2
1.2
1.2
1.0
1.0
1.0
Overload
Burst
b
c
capacity
pres-
sure
bar
bar
1
1.5
1.6
2.4
2.4
3.6
4
6
6.4
9.6
10
15
16
24
24
36
40
60
64
96
100
150
160
240
240
360
400
600
320
800
500
1250
600
1200
900
1800
4
5
2.4
3
6
7.5
12
15
20
25
36
45
60
75
96
120
2.4
3
4
5
6.4
8
10
12.5
16
20
24
30
40
50
64
80
100
125
33