Fig.: Fire monitors mounted
For installation of the fire monitors, also refer to the following schematic drawing.
Cut the monitor hoses 9.20 and 9.21 to length and attach them to the pressure pipes.
Insert the monitor and fix it with the self-tapping screws 9.22.
Connect the hoses 9.20 and 9.21 with the T-piece 9.24.
Fit the pump with interference suppression capacitor and solder the connection cables.
Connect hoses 9.28 and 9.29 to the pump. Screw the pump into the fuselage and push the suction hose onto
the connection piece 9.23. Connect the pressure hose to the T-piece.
9.21
9.20
9.24
9.28
9.29
Pump
OUT
IN
9.23
Fig.: Connection diagram for fire extinguishing monitors and pump
Status 25. August 2022
37