4.2
Storage tank installation with accessories
4.2.1
Dimensions
4.2.2
Installation requirements
®
The tubra
-nemux-S/M can be attached directly to a buffer storage tank (with
-
simultaneous piping on the heating side) by means of a connection set.
The storage tank must have a 1 ½" internal thread so that the station can be
-
connected.
The upper flow pipe can be shortened. The lower pipe has a constant length
-
The storage tank connections are arranged vertically one above the other.
-
The distances between the connections are within the illustrated range.
-
For further information, please refer to the separate instructions for the connection
-
set.
908.19.08.00
Last updated 2022/03/15
To adapt to the size of the buffer
tan, the upper flow pipe can be
adapted to the required length,
and the connection is made via a
compression fitting.
For larger distances, the upper
flow pipe Cu 22*1 must be
extended
- 9 -
GB