All manuals and user guides at all-guides.com
Digital signals, monitorings, messages
Code
No.
Name
C0410 Free configuration of digital input signals
1 NSET1-JOG1/3
2 NSET1-JOG2/3
3 NSET1-CW/CCW
4 NSET1-QSP
5 NSET1-RFG1-STOP
6 NSET1-RFG1-0
7 MPOT1-UP
8 MPOT1-DOWN
9 Reserved
10 CINH
11 TRIP set
12 TRIP reset
13 PAR-B0
14 PAR-B1
15 MCTRL1-DCB
16 Reserved
17 NSET1-H/Re
18 PCTRL1-I-OFF
19 PCTRL1-OFF
20 Reserved
21 PCTRL1-STOP
22 CW/QSP
23 CCW/QSP
24 DFIN1-ON
C0425o * Configuration frequency input X3/E1 (DFIN1)
C0426* Gain frequency input X3/E1 (DFIN1-GAIN)
C0427 Offset frequency input X3/E1 (DFIN1-OFFSET)
C0415 Free configuration digital outputs
1 Relay output K1 (Relay)
2 Digital output X3/A1 (DIGOUT1)
3 Digital output X3/A2 (DIGOUT2)
C0119o Configuration PTC input/earth-fault detection
2
C0120 I
t switch off
Important Lenze settings
Possible settings
Lenze
Selection
Digital signal source
1
X3/E1
2
X3/E2
4
X3/E4
0
0
0
0
0
0
not assigned
not assigned
0
0
0
0
0
3
X3/E3
0
0
0
0
not assigned
not assigned
0
0
0
0
0
-2-
Frequency Resolution
10 kHz
100
-1500.0
0.0
-100.0
25
TRIP fault message
16
Ready for operation
0
not assigned
-0-
PTC input not active; earth-fault detection active
0
0 (not active)
EDM82MVDG 1.0 D/GB/F
Scanning
Max. fre-
rate
quency
1/200
10 ms
10 kHz
{0.1 %}
1500.0
{0.1 %}
100.0
{1 %}
200
33