Important Lenze settings
Analog signals
Code
No.
Name
C0001o Setpoint selection (operating mode)
C0034o Setpoint selection range -
standard–I/O
Setpoint selection range -
application–I/O
C0412 Free configuration of analog input
signals
1 Setpoint 1 (NSET1–N1)
2 Setpoint 2 (NSET1-N2)
3 Additional setpoint (PCTRL1-NADD)
4 Process controller setpoint 1
(PCTRL1-SET1)
5 Act. process controller value
(PCTRL1-ACT)
6 Torque setpoint (MCTRL1-MSET)
7 Free analog signal (AFREE)
8 MCTRL1-VOLT-ADD
9 MCTRL1-PHI-ADD
C0413* Offset analog inputs
1 AIN1-OFFSET
2 AIN2-OFFSET
C0414* Gain analog inputs
1 AIN1-GAIN
2 AIN2-GAIN
C0419 Free configuration analog outputs
1 X3/62 (AOUT1-IN)
2 X3/63 (AOUT2-IN)
3 X3/A4 (DFOUT1-IN)
C0108* Gain analog output X3/62
(AOUT1-GAIN)
C0109* Offset analog output X3/62
(AOUT1-OFFSET)
C0420* Gain analog output X3/63
(AOUT2-GAIN)
C0422* Offset analog output X3/63
(AOUT2-OFFSET)
32
EDM82MVDG 1.0 D/GB/F
All manuals and user guides at all-guides.com
Possible settings
Lenze
-0-
-0-
-7-
1
1
0
0
0
0
0
0
0
0.0
0.0
100.0
100.0
0
2
3
128
0.00
128
0.00
Selection
Setpoint selection via AIN1 (X3/8 or X3/1U, X3/1I)
X3/8:
0 ... 5 V / 0 ... 10 V / 0 ... 20 mA
X3/1U:
0 ... 5 V / 0 ... 10 V
X3/2U:
0 ... 5 V / 0 ... 10 V
Analog signal source
X3/8 or X3/1U, X3/1I (AIN1-OUT)
X3/8 or X3/1U X3/1I (AIN1 OUT)
not assigned
not assigned
-200.0
200 0
{0.1 %}
{0 1 %}
-1500.0
1500 0
{0.1 %}
{0 1 %}
Analog signal source
Output frequency (MCTRL1-NOUT)
Apparent motor current (MCTRL1-IMOT)
DC-bus voltage (MCTRL1-DCVOLT)
0
{1}
-10.00
{0.01 V}
0
{1}
-10.00
{0.01 V}
200.0
200 0
1500.0
1500 0
255
10.00
255
10.00