Lenze 8200 motec Instructions De Montage page 32

Masquer les pouces Voir aussi pour 8200 motec:
Table des Matières

Publicité

Important Lenze settings
How to read the code table:
Column
Abbreviation
Code
Code
Cxxxx
1
2
Cxxxx*
Cxxxxo
[Cxxxx]
Name
Lenze
È
Selection
1
{1 %}
Operation
Code
No.
Name
C0003o Non-volatile parameter saving
C0517 User menu
1 Memory 1
2 Memory 2
3 Memory 3
4 Memory 4
5 Memory 5
6 Memory 6
7 Memory 7
8 Memory 8
9 Memory 9
10 Memory 10
[C0469]* Function of key
Acceleration, deceleration, braking, stopping
Code
No.
Name
C0012 Acceleration time main setpoint
C0013 Deceleration time main setpoint
C0182* Integration time S–ramps
C0220 Acceleration time additional setpoint
C0221 Deceleration time additional setpoint
C0105 Deceleration time QSP
C0035*o Selection DCB
C0036 Voltage/current DCB
C0107 Holding time DCB
C0196*o Activation of auto–DCB
C0019 Operating threshold auto DCB
C0106 Holding time auto DCB
[C0174]* Threshold for brake transistor
30
EDM82MVDG 1.0 D/GB/F
All manuals and user guides at all-guides.com
Meaning
Code Cxxxx
Subcode 1 of Cxxxx
Subcode 2 of Cxxxx
The parameter value of the code is the same in all parameter sets.
Changed parameters will be accepted after pressing
Changed parameters will be accepted after pressing
inhibited.
Name of the code
Lenze setting (value set at delivery or after overwriting of C0002 with Lenze setting).
Controller-dependent setting.
99 Min. value
Possible settings
Lenze
-1-
50
52
53
54
11
12
13
16
s
21
22
-1-
Possible settings
Lenze
5.00
5.00
0.00
5.00
5.00
5.00
-0-
È
999.00
-0-
0.10
0.50
100
D
D
The parameter value of the code can be defined
The parameter value of the code can be defined
differently for each parameter set.
differently for each parameter set.
D
The parameter value is accepted immediately (ONLINE).
{Steps/unit}
Max. value
Selection
Parameter is saved on EEPROM
C0050
Output frequency (MCTRL1-NOUT)
C0052
Motor voltage (MCTRL1-VOLT)
C0053
DC-bus voltage (MCTRL1-DCVOLT)
C0054
Apparent motor current (MCTRL1-IMOT)
C0011
Maximum output frequency
C0012
Acceleration time main setpoint
C0013
Deceleration time main setpoint
C0016
V
boost
min
C0021
Slip compensation
C0022
I
limit in motor mode
max
CINH (controller inhibit)
Selection
0.00
{0.02 s}
0.00
{0.02 s}
0.00 (no S-ramps)
{0.01 s}
0.00
{0.02 s}
0.00
{0.02 s}
0.00
{0.02 s}
Selection of brake voltage under C0036
0
{0.02 %}
1.00
{0.01 s}
Auto DCB active if C0050 < C0019
0.00
{0.02 Hz}
0.00
{0.01 s}
78
v
v
, if the controller is
1300.00
1300.00
50.00
1300.00
1300.00
1300.00
150 %
999.00
480.00
999.00
{1 %}
110

Publicité

Table des Matières
loading

Table des Matières