Wiring The Vac Models; Wiring The Vac Model 224Xst; Wiring The Vac Model 225Xst - Federal Signal Electraray 224XST Instructions D'installation Et D'entretien

Masquer les pouces Voir aussi pour Electraray 224XST:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation and Maintenance Instructions

Wiring the Vac Models

The 120 Vac or 230-240 Vac strobe lights are designed to operate on
both 50 and 60 Hz electrical power. Special modifications are NOT
required for the two different AC line frequencies.

Wiring the Vac Model 224XST

The 224XST Vac light is provided with five leads: two black, two
white, and one green/yellow.
To achieve electrical supervision:
1. Connect one black lead to the phase (line) side of the incoming
power source and the other black lead to the phase (line) side
of the outgoing power.
2. Connect one white lead to the common (neutral) side of
the incoming power source and the other white lead to the
common (neutral) side of the outgoing power.
3. Connect the green/yellow lead to earth ground.

Wiring the Vac Model 225XST

The 225XST Vac light is provided with three leads: one black, one
white, and one green/yellow.
To wire the light:
1. Connect the black lead to the phase (line) side of the AC
power source.
2. Connect the white lead to the common (neutral) side of the AC
power source.
3. Connect the green/yellow lead to earth ground.