ENGLISH
The Raychem ETS-05 electronic
surface sensing thermostat provides
accurate temperature control for
heating cables. The ETS-05 is
available in the following versions:
ETS-05-L2-E
ETS-05-H2-E
ETS-05-L1-J
ETS-05-H1-J
With:
L = 0°C-199°C,
H = 0°C-499°C
1 = 110V AC
2 = 230V AC
E = Europe & Asia
J = Japan
These Thermostats are suitable for
the following applications:
Current Rating: 32A
Hazardous area:
(Zone 0)* Zone 1 and Zone 2
(*Only sensor may be located within
Zone0)
Temperature Class: T5
Gas Group IIC
Dust (Zone 21 and Zone 22)
Dust Group IIIC
Installation instructions for ETS-05
Approvals:
Pentair
1180
II 2(1)G
II 2D
Ex e ia mb [Ga] IIC T5 Gb
Ex tb IIIC T100°C Db IP66
Ta-40 to +60°C
Supply = 99-121V (110V) or
195-230V (230V)
Maximum switched current
32A Resistive
Um=253V
Baseefa13ATEX0137
IECEx BAS 13.0071
Please note: Only Ex e and Ex tb
equipment certified cable glands
or stopping plugs which employ
a sealing washer or gasket may
be used.
TC RU C-BE.ME92.B.00480
Ex e mb ia [Ga] IIC T5 Gb
Ex tb IIIC T100°C Db IP66