INSTALLATION AND OPERATION MANUAL
APPROVALS
TECHNICAL DATA
Supply voltage
Maximum switching current
GFCI
Ambient setpoint range
Floor setpoint range (F mode) 40°F to 104°F (5°C to 40°C)
Floor limit setpoint range
Operating temperature range 32°F to 120°F (0°C to 50°C)
Storage temperature range
KIT CONTENTS
Item Qty
Description
A
1
QuickStat-TC thermostat
B
2
Mounting screws
C
1
Floor temperature sensor 15 ft (4.6m)
D
5
Wire nuts
E
1
Screwdriver
THERMAL BUILDING SOLUTIONS
QuickStat-TC
F
A
2
120 V, 208 V, 240 V, 60 Hz
15 A
Class A, 5 mA trip level
40°F to 86°F (5°C to 30°C)
(A/AF mode)
40°F to 104°F (5°C to 40°C)
(AF mode)
–4°F to 120°F (–20°C to 50°C)
EN-RaychemQuickStatTCthermostat-IM-H58517 10/14
GENERAL INFORMATION
Use of this Manual
This manual covers the installation and operation of the Raychem
QuickStat-TC thermostat and must be used with the following
documents:
• QuickNet System Installation Manual (H57704)
• CeraPro System Installation Manual (H58956)
Important: For the Pentair Thermal Management warranty
and agency approvals to apply, the instructions included in this
manual and product packages must be followed.
Features
The QuickStat-TC is an electronic thermostat that must be used
with the Raychem QuickNet floor heating mats and CeraPro floor
heating cables.
QuickStat-TC provides the following features:
• Integrated Class A, Ground-Fault Circuit Interrupter (GFCI).
• Operates at 120 V, 208 V, and 240 V at 60 Hz
• Switches on your heating system at predetermined times on
different days of the week.
• Offers 4 periods each day that you can set at different
temperatures.
• Comes with a preprogrammed schedule that is suitable for most
installations. However, you can customize this program any time
you wish.
• Allows you to reset the thermostat to factory settings.
• Changes the start time of a heating period automatically so that
the desired temperature is reached at the time that you set.
• Multiple temperature control options so users can control the
system based on floor temperature (F), ambient air temperature
(A), or both (AF).
• On/Off switch to turn off thermostat during summer months.
A
B
C
D
E
1 / 6