Danger due to emerging wire electrode.
This can result in serious personal injuries.
▶
▶
▶
▶
Danger due to hot system components and/or equipment.
Can result in serious burns or scalding.
▶
▶
Danger from operation without coolant.
This can result in damage to property.
▶
▶
▶
Danger due to exposed mechanically moving parts.
This can result in personal injury and damage to property.
▶
System require-
Power source
ments
-
-
Software
-
-
Options
-
-
20
WARNING!
Hold the welding torch so that the tip of the welding torch points away from
the face and body.
Wear suitable protective goggles.
Do not point the welding torch at people.
Ensure that the wire electrode does not touch any electrically conductive ob-
jects.
WARNING!
Before starting work, allow all hot system components and/or equipment to
cool to +25°C/+77°F (e.g., coolant, water-cooled system components, wire-
feeder drive motor, etc.)
Wear suitable protective equipment (e.g., heat-resistant gloves, safety gog-
gles, etc.) if cooling down is not possible.
CAUTION!
Never operate water-cooled welding torches without coolant.
During welding, ensure that the coolant is circulating correctly – this will be
the case for Fronius cooling units if a regular return flow of coolant can be
seen in the coolant container of the cooling unit.
The manufacturer will not be liable for any damages due to non-observance
of the above mentioned points. All claims against the warranty are void.
CAUTION!
Only operate the device when all covers are closed and/or completely moun-
ted.
TS 4000 / 5000
TPS 2700 / 4000 / 5000
Power source: Software version 3.10.22 or higher
Wire feed: Software version 1.70.16 or higher
Installation set „PMR4000 PullMig TS/TPS 2700-5000 (4,100,217)"
Software „FS Drive (4,061,113)"