Read before proceeding:
•
Use cold water only . Include a shut-off valve in the water line for maintenance purposes .
•
Use primary and secondary water filters .
•
Install the vented loop as shown in figures 13 and 14 . It must be equipped with an
integral check valve that allows air into the line to prevent siphoning .
•
The raw water pump must not be demand-type . The pump is controlled by a
control module .
13
0.625" (16 mm) Hose
1" (25 mm) Hose
Seacock
Small Engine
Intake Strainer (coarse)
14
0.625" (16 mm) Hose
1" (25 mm) Hose
Seacock
5.3
Wiring/electronic control module connections
I
Read before proceeding:
•
There must be a circuit breaker or fuse for every toilet .
•
For marine applications, follow ABYC guidelines .
•
For RV applications, refer to ANSI/RVIA LV and NFPA70/NEC standards (U .S .A .)
or CEC I and II standards (Canada) for the recommended wire gauge . Refer to"1 .3
Supplemental directives" on page 3 .
•
Use tinned, stranded copper wire .
•
Use crimp-type wire connections . Do not use wire nuts, as wire nuts can corrode .
5.4
Planning the electrical connections
➤ Plan the flush-switch panel and electronic control module locations, if applicable, so that the
control module and wires are installed in locations that will always remain dry .
I
Several flush-switch assembly options are available from Dometic . Follow the instructions
included with each flush switch assembly .
9
Vented Loop/Check Valve
(Must be 8" (203 mm) min. above
water line during all conditions
Water Line
To Suction Side of
Raw Water Pump
Fine Water Filter
(100 Mesh)
Vented Loop/Check Valve
(Must be 8"(203 mm) min. above
water line during all conditions
Water Line
To Suction Side of
Raw Water Pump
Fine Water Filter
(100 Mesh)
Small Engine
Intake Strainer (coarse)
of heel, trim, or load)
Raw Water
Pump
0.5" (13 mm)
Water Hose
of heel, trim, or load)
Raw Water
Pump
0.5" (13 mm)
Water Hose
Toilets
Flush-
Switch
Panel
Macerator Toilet
Flush
Switch
Control
Module
Macerator Toilet
EN