2. Pour obtenir la liste des pannes actuelles du serveur, tapez :
faultmgmtsp> fmadm faulty
----------------- ------------------------------------- -------------- --------
Time
----------------- ------------------------------------- -------------- --------
2010-09-03/20:46:23 fa4a2f86-5156-4243-8e88-d6516db12970 SPT-8000-DH
Fault class : fault.chassis.voltage.fail
FRU
: /SYS/MB
(Part Number: 541-4197-04)
(Serial Number: 1005LCB-1025D40059)
Description : A chassis voltage supply is operating outside of the
allowable range.
Response
: The system will be powered off.
required LED will be illuminated.
Impact
: The system is not usable until repaired.
the system to be powered on until repaired.
Action
: The administrator should review the ILOM event log for
additional information pertaining to this diagnosis.
refer to the Details section of the Knowledge Article for
additional information.
Remarque – Si le serveur détecte le remplacement de la FRU défectueuse, la
réparation ne nécessite pas l'exécution d'une commande par l'utilisateur, car la
panne sera effacée automatiquement.
3. Détectez des informations complémentaires sur une panne donnée.
Recherchez la panne MSG-ID (SPT-8000-DH dans l'exemple précédent), et
saisissez-la dans la fenêtre de recherche Search Knowledge Base (Rechercher dans
la base de connaissances) sur le site http://support.oracle.com.
4. Pour plus d'informations sur la réparation de la panne, reportez-vous à la
section :
« Pour corriger une panne (shell de gestion des pannes d'Oracle ILOM) », page
66
Guide d'administration des serveurs de la série SPARC T4 • Novembre 2011
UUID
msgid
The chassis-wide service
ILOM will not allow
Severity
Critical
Please
69.