System messages

The 4-digit system message is displayed as two groups of two digits appearing in succession.
System message
Functions that are still
available
E
r
1
1
E
r
1
1
Container cover raised
E
E
r
r
2
2
2
2
Water temperature > 12 °C
AND the last automatic
cleaning process was carried
out more than 24 hours ago.
Possible cause
Manual cleaning (only
Container cover raised
nozzles, filter drum not
Container cover incorrectly fitted
rotating)
Signal box not connected
Manual cleaning
Screen elements leaking
Automatic mode
Drum seal leaking
Time-dependent cleaning
Level detection device stuck or
defective
Level detection device set incorrectly
Remedy
Refit the container cover
Turn the container cover around so that the magnets in the
container cover are located over the signal box
Connect the signal box to the control system
Check screen elements, replace if necessary
Check the drum seal
Clean the level detection device to ensure that the
mechanics operate freely, replace if necessary
Adjust the level detection device (→ Adjusting the level
detection device)
- GB -
Resetting the system
message
Automatic when the
container cover is replaced
On|Off
Press the key
for 5 s
Automatic as soon as the
level detection device is
triggered