- GB -
System message
Functions that are still
available
E
r
5
5
E
r
5
5
More than 960 cleaning
−
cycles in 48 hours
−
−
E
E
r
r
6
6
6
6
Switch element for rinsing
None
pump in the control system
overheated
62
Possible cause
Manual cleaning
Temporary heavy soiling
Automatic mode
Start-up phase of the filter system
−
Time-dependent cleaning
(e.g. during the first start-up)
Fish are spawning
−
Pond heavily soiled
Screen elements heavily soiled
Insufficient cleaning effect due to soiled
nozzles
Water level in the system too high:
Outlet pipes soiled
−
Outlet opening too small
−
Max. flow quantity exceeded
−
Control system is exposed to excessive
heat (sun, ambient temperature)
Remedy
Wait until the soiling decreases
This operating status is atypical. Avoid long-term operation
−
in this state.
Clean the pond
−
Reduce the amount of soiling
−
Clean and decalcify screen elements (→ Replacing screen
element)
Clean the nozzles
−
Clean outlet pipes
−
Enlarge outlet opening
−
Reduce flow rate
−
Protect the control system from heat
Resetting the system
message
On|Off
Press key
for 5 sec
−
Automatic if the number of
−
cleaning procedures drops
below 960.
Automatic when cooled down