13.Check the fuel system periodically for leaks or
signs of deterioration such as chafed or spongy
hose, loose or missing clamps, or damaged tank or
cap. All defects should be corrected before
operation.
14.The generator should be operated, serviced, and
refueled only under the following conditions:
a. Start and run the generator outdoors. Do
not run the generator in an enclosed area,
even if doors or windows are open; avoid
areas where vapors may be trapped, such as
pits, garages, cellars, excavations and boat
bilges. DANGER - CARBON MONOXIDE
HAZARD: The engine exhaust contains
carbon monoxide, a poisonous, odorless,
invisible gas which, if breathed, may cause
death or serious personal injury. If you start
to feel sick, dizzy or weak while using the
generator, shut it off and get to fresh air
right away; you may have carbon monoxide
poisoning.
b.Good ventilation for cooling. Air flow and
temperatures are important for air cooled
units. Temperatures should not exceed 104º
F ambient (40º C).
c. Refuel the generator in a well lighted area.
Avoid fuel spills and never refuel while the
generator is running. Allow engine to cool for
two minutes prior to refueling.
d. Do not refuel near open flames, pilot lights, or
sparking electrical equipment such as power
tools, welders, and grinders.
e. The muffler and air cleaner must be installed
and in good condition at all times as they
function as flame arresters if backfiring occurs.
f. Do not smoke near the generator.
15.Ensure that generator is properly grounded. (See
"Grounding the generator" section in this
manual.)
16.Do not wear loose clothing, jewelry, or anything
that may be caught in the starter or other rotating
parts.
17.Unit must reach operating speed before electrical
loads are connected. Disconnect loads before
turning off engine.
18.To prevent surging that may possibly damage
equipment, do not allow engine to run out of fuel
when electrical loads are applied.
19.When powering solid state equipment, a Power
Line Conditioner should be used to avoid possible
damage to equipment.
20. Do not stick anything through ventilating slots,
even when the generator is not operating. This can
English
damage the generator or cause personal injury.
21.Before transporting the generator in a vehicle,
drain all fuel to prevent leakage that may occur.
22.Use proper lifting techniques when transporting
the generator from site
to site. Improper lifting
techniques may result
in personal injury.
23.To avoid burns, do not touch engine muffler or
other engine or generator surfaces which became
hot during operation.

CALIFORNIA PROPOSITION 65 WARNING

The engine exhaust from this product contains chemicals
known to the State of California to cause cancer, birth defects,
or other reproductive harm.

SPARK ARRESTER

SPARK ARRESTER
YOUR PRODUCT MAY NOT BE EQUIPPED WITH A
SPARK ARRESTING MUFFLER. If the product will be
used around flammable materials, such as agricultural crops,
forests, brush, grass, or other similar items, then an approved
spark arrester should be installed and is legally required in the
State of California. The California statutes requiring a spark
arrester are Sections 13005(b), 4442 and 4443. Spark
Arresters are also required on some U.S. Forest Service land
and may also be legally required under other statutes and
ordinances. For more information, contact Powermate, LLC,
Marietta, Georgia 30062. 1-800-445-1805
4
Customer Hotline 1-800-445-1805