Moteur à essence à soupapes en tête, 270 cm cubes avec démarrage
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

V2.7
ASSEMBLY
The engine comes assembled.
OPERATION
PRE-OPERATION CHECKS
CAUTION! The engine is not shipped with oil. Before starting the engine, add oil according to the instructions in this
manual. Starting the engine without oil will damage the engine beyond repair.
Check the engine's condition before operating to maximize the user's safety and the service life of the engine. Ensure
that the engine is level and the switch is in the OFF position before beginning the pre-operation checks.
GENERAL CONDITION
1. Look around and underneath the engine for signs of oil or gasoline leaks.
2. Remove any excessive dirt or debris, especially around the muffler (B) and recoil starter (E).
3. Look for signs of damage.
4. Check that all shields and covers are in place.
5. Check that all nuts, bolts, and screws are tight.
CHECK THE ENGINE
1. Check the fuel level. This will save time for refuelling later.
2. Check the engine oil level. Running the engine with a low oil level can cause engine damage (see How to
Check/Add Oil).
3. Check the air filter element. A dirty air filter will reduce engine performance (see How to Service the
Air Filter).
4. Check the equipment powered by this engine.
5. Review the instructions provided with the equipment powered by this engine for precautions and procedures
that should be followed before starting the engine.
BEFORE STARTING THE ENGINE
WARNING! Do not start or run engine in enclosed area, even if doors or windows are open. Engine exhaust contains
carbon monoxide, an odourless and colourless poison gas.
1. Make sure spark plug (C), muffler (B), fuel cap (K) and air cleaner (A) are in place and secured. Do not crank
engine with spark plug removed.
2. Ensure spark plug lead is securely connected to spark plug, otherwise unintentional sparking can result,
causing fire or electric shock.
3. Do not start the engine until any spilled fuel has evaporated.
NOTE: Some engine applications have a remote-mounted choke control installed rather than the engine-mounted
choke lever shown here. Refer to the instructions provided by remote
equipment manufacturer.