Commissioning/Decommissioning
6.1.3
Switch the overhang counter swim unit on
Pre-requisites:
•
Unit must be filled with water
•
Cover must be on
NOTICE
The pump can be damaged if it runs dry!
Purge air from the pump and suction line.
1.
Switch the pump/unit on.
NOTICE
If the pump has a three-phase motor and it turns in the wrong
direction, the pump/unit is louder and has a lower capacity.
2.
For three-phase motors: Ensure that the motor turns in the
direction of the arrow labeled on the fan hood. If the motor
rotates in the wrong direction, notify an electrician.
This can also be carried out when the cover is not on by
pressing the contactor.
3.
Check the mechanical seal for leaking.
6.2
Operation
6.2.1
Switching the unit on and off
The unit can be switched on and off by pressing the pneumatic
button (2/1) which is built into the cover. There is no electrical
operating unit in the pool.
6.2.2
Volume regulator
The performance of the pump can be controlled using the
adjustable nozzle (54/1). In this way, each swimmer can set the
nozzle stream individually.
CAUTION
Injury due to massage with full nozzle stream.
Maintain a sufficient distance in order to avoid damage to
health.
NOTICE
The pump/unit may be damaged due to operation with a closed
volume regulator.
Only operate the pump/unit with an open volume regulator.
30 EN
10|2020