8
Maintenance
NOTICE
Before maintenance work, close all shut-off valves and drain
all pipes.
When?
Regularly
If there is a
chance of frost
After completing all maintenance work, perform all necessary
measures for start-up. See point 6.1 on page 28.
8.1
Care Instructions
If needed, wash the unit with water and wipe with a damp cloth.
Do not use abrasive cleaning agents!
A few sprays of a cleaning agent especially for use on acrylic
surfaces can be used occasionally. Wipe with a clean, dry cloth.
Heavily soiled surfaces can be cleaned with warm soapy water or
a mild cleanser.
Limescale deposits/water spots can be removed with a mixture of
spirit vinegar and water. Removal of light scratches or rough spots
on shiny surfaces can be carried out using a care kit found in
sanitary supply stores.
8.2
Warranty
The warranty includes the devices delivered and all components.
However natural wear and tear (DIN 3151/DIN-EN 13306) on all
turning and dynamically loaded components, including electronic
components under tension, is not covered under the warranty.
Failure to comply with the safety instructions may void the
warranty.
8.2.1
Safety related spare parts
–
Safety switch (cover)
–
Guide wall
–
Telescopic support foot
10|2020
What?
Check the pump is not leaking
Check the stability of the unit, all
impurities should be removed
Check the electrical contacts in general
Separate potential connector
Remove the unit from the pool. Empty
and store it in a dry location.
Maintenance
EN 37