LERBAKKEN 10, 8410 ROENDE DENMARK
9116Bx-U9 Installation:
Hazardous Classified Location
Class I/II/III, Division 1, Group A,B,C,D,E,F,G
Zone 0,1, 2 Group IIC, IIB, IIA or
Zone 20, 21
0/4-20 mA
+
Current source
-
Module 9116B2-U9
Group
Terminal 52-51,51-52
Voc, Uo
16.6 V
IIC or A,B
Isc, Io
0.2 mA
IIB or C,E,F
Po
0.8 mW
IIA or D,G
Revision date:
2019-11-26
-20 ≤Ta ≤ +60ºC
4501
54
53
52
51
44
43
42
41
9116
Power Rail
4501
54
53
52
51
44
43
42
41
9116
Power Rail
Ca or Co
La or Lo
Lo/Ro
0.4µF
1000 mH
25 mH/Ω
2.3µF
1000 mH
100mH/Ω
9.5µF
1000 mH
200mH/Ω
Version Revision
V1 R0
9116 - Version de produit 9116-003
Unclassified Location or
Hazardous Classified Location
Class I, Division 2, Group ABCD T4
Class I Zone 2 Group IIC T4
Supply terminal
34
33
Voltage:
32
Status relay, terminal (33,34)
31
Class I Division 2 or
14
Zone 2 installation:
13
Voltage max:
12
Current max:
11
Relay output, terminal (13,14)
Class I Division 2 or
Zone 2 installation
Voltage max:
Power max:
Current max:
34
33
(terminal 11,12,13,14)
32
(terminal 31,32,33,34)
31
(terminal 91,92,93,94,95)
U
m:
14
13
12
11
9116B1-U9 and 9116B2-U9
Terminal 51-52
Vmax or Ui: 30V;
Imax or Ii:120mA;
Pi:900mW;
Ci:6nF;
Li:2µH
Prepared by:
PB
9116QU01
(31,32)
19.2 – 31.2 VDC
32 Vac/ 32 Vdc
0.5 Aac / 0.3Adc
32 V AC / 30 VDC
64 VA / 60 W
2 A AC / 2 ADC
253 V max. 400 Hz
Page:
6/7
49