FAULT
• The heater works erratically and the burner
goes on and off alternately:
lamp
goes on and off
• The heater does not work:
lamp
is on
• The heater does not work:
lamp
flashes
• The heater does not work:
lamp
is steady on
Number of flashes of lamp (d)
• Fan is noisy or vibrates
• Insufficient heating
L-L 195.00-BM
CAUSE
• Gas flow
• Burner thermostat has tripped due to
overheating
• Manual reset safety thermostat has tripped due
to excessive overheating of combustion
chamber
• Voltage control has tripped due to insufficient
electrical supply (V < 190V)
THE BUTTON LAMP FLASHES WITH 2 TO 7 FLASHES
2
• No flame during ignition cycle
• Air pressure switch has tripped (electrical
3
contact remained open) at start of ignition cycle
• Parasite flame detected in pre-wash phase
4
during ignition cycle
• Air pressure switch has tripped (electrical
5
contact has opened) during ignition cycle
• Air pressure switch has tripped (electrical
6
contact has opened) during work cycle
7
• No flame during work cycle
• Dirt on fan blades
• Poor air circulation
• Insufficient burner capacity
EN
• Check and clean gas filter.
• Clean and recalibrate the burner.
• Check correct position of air distribution channels
and opening of any flaps, openings, etc.
• Remove any foreign bodies trapped in the air ducts or
ventilation grilles
• Check that the fan motor starts correctly and is not
obstructed
• Check that the fan motor is not burned out or that the
motor condenser is not broken
• Check burner calibration
• Check the chimney and correct discharge of fumes
• The heater restarts automatically when sufficient
voltage is restored (V>190V)
• Check the power line if the heater starts and stops
several times
• Check the power line if the heater does not start and
remains in safety stop
LAUNCH THE SELF-DIAGNOSIS PROCEDURE
PUSH BUTTON (D) FOR 7 SECONDS AND RELEASE:
• Check gas pressure at burner
• Check and clean gas filter
• Check that ionisation probe is not discharging to
earth
• Check ionisation probe connection cables (they must
not discharge to earth)
• Check connection of pressure switch pipes
• Check pressure switch and replace if necessary
• Check that there are no gas pockets in the
combustion chamber
• Check that ionisation probe is not discharging to
earth
• Check ionisation probe connection cables (they must
not discharge to earth)
• Check connection of pressure switch pipes
• Check that burner motor and fan are not blocked or
broken; replace if necessary
• Check that smoke exhaust chimney is not partially or
totally obstructed
• Check pressure switch and replace if necessary
• Check connection of pressure switch pipes
• Check that burner motor and fan are not blocked or
broken; replace if necessary
• Check that smoke exhaust chimney is not partially or
totally obstructed
• Check pressure switch and replace if necessary
• Check gas pressure at burner
• Check and clean gas filter
• Check that ionisation probe is not discharging to
earth
• Check ionisation probe connection cables (they must
not discharge to earth)
• Remove dirt
• Eliminate all obstacles to air flow
• Contact Customer Service
REMEDY