12. Troubleshooting

Fault
Possible cause
The compressor does
• No supply voltage.
not start.
• Insuffi cient supply voltage.
• Outside temperature is too low.
• Motor is overheated.
The compressor starts
• The non-return valve leaks.
but there is no pressure.
• The seals are damaged.
• The drain plug for condensation water (10)
leaks.
The compressor starts,
• The hose connections have a leak.
pressure is shown on
the pressure gauge, but
• A quick-lock coupling has a leak.
the tools do not start.
• Insuffi cient pressure set on the pressure
regulator (4).
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
DE
All manuals and user guides at all-guides.com
GB
FR
IT
CK
SK
Remedy
• Check the supply voltage, the power plug and the
socket-outlet.
• Make sure that the extension cable is not too
long. Use an extension cable with large enough
wires.
• Never operate with an outside temperature of
below +5° C.
• Allow the motor to cool down. If necessary,
remedy the cause of the overheating.
• Have a service center replace the non-return
valve.
• Check the seals and have any damaged seals
replaced by a service center.
• Tighten the screw by hand. Check the seal on the
screw and replace if necessary.
• Check the compressed air hose and tools and
replace if necessary.
• Check the quick-lock coupling and replace if
necessary.
• Increase the set pressure with the pressure
regulator.