_ECL-75_102.book Seite 43 Donnerstag, 6. Mai 2010 4:43 16
ECL-75, ECL-102
Dometic B2200 / B1600 Plus
Note
B 2200 with a serial number lower than 802200001 must be installed as
described in chapter 7.2.
➤
Remove the B2200 / B1600 Plus's outlet panel, if necessary remove the upper
cover.
➤
Connect the wire sleeves of the universal connection cable to contacts I5 and I2
on the charging current distributor.
➤
Join the on/off cable of the B2200 / B1600 Plus (item no. 4441300129) to the plug
connector on the circuit board (see fig. 10, page 11).
Note
Guide the on/off cable carefully past the fan.
➤
Connect both the wires on the universal connection cable (4441300124) to the two
wires on the on/off cable of the B2200 / B1600 Plus.
7.5
DC-Kit-3 with Dometic B1600 / HB2500
Circuit diagram, see page 9
Roof air conditioner: Dometic B1600 / HB2500
Charging current distributor: ECL-102
Inverter: SinePower SP1500 (item no. MSK1500-012)
➤
Install inverter remote control MCR-8 (or MCR-9, membrane button) in an
easily-accessible place (jumper closed, refer to remote control installation manual)
and connect its cable to the inverter.
➤
Unravel the 2-wire universal connection cable (on/off cable, item no. 4441300124)
so that you have two individual wires.
➤
Use the blue wire of the universal connection cable (item no. 4441300124) to
join the I5 connection of the ECL-102 to the MCR-8 (MCR-9) remote control
(use wire sleeves).
➤
Use the brown wire of the universal connection cable to join the D+ input to the
l2 connection on the ECL-102 (use wire sleeves).
8
Adjustment
Caution
The following work must be carried out with caution and only by persons with
the necessary skills and knowledge. This is because incorrect adjustment of
the cut-in and cut-off voltages can cause the air conditioner to malfunction and/
or cause the vehicle's electrical system to fail.
All manuals and user guides at all-guides.com
Adjustment
43