Connection
Connect the wire sleeves of the universal connection cable to contacts I5 and I2
on the charging current distributor.
Join the on/off cable of the B2200 / B1600 Plus (item no. 4441300129) to the plug
connector on the circuit board (see fig. 10, page 11).
Note
Guide the on/off cable carefully past the fan.
Connect both the wires on the universal connection cable (4441300124) to the two
wires on the on/off cable of the B2200 / B1600 Plus.
7.4
DC kit 3 with Dometic CA1000 / CA2500 / B2200 / B1600 Plus
Circuit diagram, see page 7 (CA1000 and CA2500) / page 8 (B2200 / B1600 Plus)
Roof air conditioner: CA1000 / CA2500 / B2200 / B1600 Plus
Charging current distributor: ECL-102
Inverter: SinePower SP1500 (item no. MSK1500-012)
Install inverter remote control MCR-8 (or MCR-9, membrane button) in an
easily-accessible place (jumper closed, refer to remote control installation manual)
and connect its cable to the inverter.
Dometic CA1000
Note
Observe also the instructions in the scope of delivery of the sensing cable.
Remove the CA1000's outlet panel.
Using the 2-wire on/off cable (sensing cable, item no. 4441300084), connect contacts I2
and I3 on the ECL-102 to the air conditioner.
Insert the three-pole plug of the sensing cable into the socket (3-pole pin strip socket)
on the control PCB of the air conditioner (see fig. 9, page 10).
Set the AC/DC switching parameters for the air conditioner to "02" (see the
installation manual for the CA1000, "Configuring the system software").
Dometic CA2500
Remove the CA2500's outlet panel.
Connect the charging current distributor to the air conditioner using the 2-wire
universal connection cable (on/off cable, item no. 4441300124).
Connect the wire sleeves of the universal connection cable to contacts 12 and 13
on the charging current distributor.
A cable leading out provides the connection to the circuit board (see fig. 11,
page 11). Sever this cable and join the resulting cable ends to the universal
connection cable.