Finish installation by tightening the compression gland nut.
Compression gland nut

2.7. Starting the product with a magnet

Once configuration of the product has been completed and its installation finalized, the product is ready to be started.
The product is started using a magnet placed on the upper part of the product (cf diagram below). The magnet must be kept in position for a
minimum of 6 seconds in order to confirm start-up of the product.
Once the SIGFOX SENSORS validates its start-up, it immediately transmits status frames followed by a data frame (according the defined perio-
dicity).
The SIGFOX SENSORS does not have an external LED showing its status. To make sure the product has started properly, we advise placing a
data receiver close to your product before start-up with the magnet. You can then receive the start-up frames and confirm that your product is
operating properly.
IMPORTANT NOTE 1: once the SIGFOX SENSORS has started, it can no longer be switched off.
All manuals and user guides at all-guides.com
Position of the magnet for
product start-up