Page 1
All manuals and user guides at all-guides.com SIGFOX SENSORS Transceiver Analog/Digital Interfaces Mode d’emploi / User Guide Version V2.1.1 Adeunis 283 rue Louis Néel - Parc Technologique Pré Roux 38920 CROLLES - France www.adeunis.com...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 TABLE DES MATIERES INFORMATIONS AVERTISSEMENTS SUPPORT TECHNIQUE DECLARATION DE CONFORMITE INTRODUCTION RECOMMANDATIONS ENVIRONNEMENTALES PREAVIS RECOMMANDATIONS D’USAGE PRESENTATION DU PRODUIT 1.1. Description générale 1.2. Encombrement 1.3.
Page 3
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 INFORMATION DISCLAIMER TECHNICAL SUPPORT COMPLIANCE DECLARATION INTRODUCTION ENVIRONMENTAL RECOMMENDATIONS WARNINGS RECOMMENDATIONS REGARDING USE PRODUCT PRESENTATION 1.1. General description 1.2. Dimensions 1.3. Electronic board 1.4.
Page 4
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 FRANCAIS Page of 45...
ADEUNIS se réserve le droit de modifier les spécifications techniques ou des fonctions de ses produits, ou de cesser la fabrication de l’un de ses produits, ou d’interrompre le support technique de l’un de ses produits, sans aucune notification écrite et demande expresse de ses clients, et de s’assurer que les informations à...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 Attention : ne pas ouvrir le produit, risque de choc électrique. Attention : pour votre sécurité, il est impératif qu’avant toute intervention technique sur l’équipement celui-ci soit mis hors tension. Attention : pour votre sécurité, le circuit d’alimentation du produit doit être de type TBTS (très basse tension de sécurité) et doit être des sources à...
NOTE IMPORTANTE : le démarrage du SIGFOX SENSORS ne peut se faire que grâce à un aimant. Description • Le SIGFOX SENSORS d’ADEUNIS est un émetteur radio prêt à l’emploi permettant de transformer tout type de capteur 0-10V, 4-20mA et TOR (Tout-Ou-Rien), en un capteur sans-fil. •...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 1.2. Encombrement Valeurs en millimètres 1.3. Carte électronique Antenne interne Module RF Batterie interne Protocole SIGFOX Switchs pour configuration produit Borniers à vis pour connexion compteurs Page of 45...
EXPLOITATION: c’est le mode dans lequel le SIGFOX SENSORS emet des trames de façon périodique. Pour passer dans ce mode d’exploi- tation, il est nécessaire d’activer le produit avec un aimant. (voir $2.6 Démarrage du produit) 1.4.5 Compatibilité capteurs Exemple de capteurs testés par Adeunis (liste non exhaustive) Type Type...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 2. PREPARATION ET CONFIGURATION 2.1. Démontage du boîtier Le produit est livré démonté, de sorte à pouvoir accéder à la partie basse de l’électronique. Cette partie permet le branchement du ou des comp- teurs sur les borniers à...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 Note: 2 capteurs au maximum peuvent être utilisés en parallèle. Le choix entre analogique et numérique est libre pour l’utilisateur. Les capteurs analogiques nécessitent une alimentation électrique que la batterie de l’AMR SENSORS n’est pas en mesure de fournir. On doit donc alimenter le capteur analogique via une source électrique externe.
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 2.4. Configurer le SIGFOX SENSORS (en entrée analogique) Dans cette configuration, le produit émet périodiquement une trame suivant la configuration choisie. Ce mode de fonctionnement n’est dispo- nible que lorsque les 2 voies sont configurées en analogique.
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 2.5. Configurer le SIGFOX SENSORS (en entrée TOR) Dans cette configuration, le produit émet une trame sur évènement, à chaque changement d’état d’une des 2 entrées TOR. La combinaison des switches permet de configurer votre SIGFOX SENSORS.
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 • Insérer la partie supérieure du boîtier. A l’intérieur de cette partie se trouvent des rails de guidage de la carte. Veiller à ce que la carte soit Ergot Clip de fixation bien positionnée à...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 2.7. Démarrage du produit via aimant Ecrou presse-étoupe Une fois la configuration du produit effectué et son montage finalisé, le produit est prêt à être démarré. Le démarrage s’effectue à...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 3. INSTALLATION ET UTILISATION 3.1. Positionnement correct des émetteurs SIGFOX SENSORS Deux règles sont primordiales pour une optimisation des portées radio. • La première consiste à positionner votre produit le plus haut possible. •...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 il est recommandé de retirer le levier de verrouillage/déverrouillage Ergots Rail-DIN. Pour retirer celui-ci, tirer vers le bas sur le levier jusqu’à ce que les Partie dégagée ergots de blocage soient face à...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 3.2.3 Fixation Rail-DIN Ce système, intégré au boîtier, permet de fixer le SIGFOX SENSORS sur un rail standard de 35mm • Pour installer le boîtier, placer les inserts supérieurs sur le rail et abaisser le produit pour le clipser •...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 4. TRAMES RADIO Le SIGFOX SENSORS transmet des informations brutes en provenance des compteurs en utilisant le réseau SIGFOX. • Une trame périodique pour la mesure des entrées analogique •...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 4.1.2 Uplink - Entrée TOR Chronogramme des émissions de trame pour le produit en configuration entrée TOR UPLINK (Case 1) 0x06 0x03 0x01 0x01 Demarrage du produit Evenement sur...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 4.1.4 Octet de status produit • Erreur batterie faible : bit à 1 si la tension est <= 2.5V, sinon 0 • Erreur de configuration switch : 1 si pas de cohérence des switchs avec le fonctionnement du produit, sinon 0 •...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 5. HISTORIQUE DE DOCUMENT User guide version Contents V2.1.1 Mise à jour Déclaration de Conformité V2.1 Mise à jour Déclaration de Conformité V2.0 Modification digital input function V1.4 Correction function error...
Page 25
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 ENGLISH Page of 45...
From ARF8047AAF/ABF/ACF/ADF DISCLAIMER This document and the use of the information it contains is subject to acceptance of ADEUNIS ’s terms and conditions. These can be down- loaded from: www.adeunis.com. ADEUNIS gives no guarantee concerning the accuracy or completeness of the contents of this document and reserves the right to make modifi- cations to product specifications and descriptions at any time without notice.
Page 27
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 Page of 45...
Under no circumstances can the manufacturer, or the distributor of an ADEUNIS program, be held liable for any damage caused by the use of the aforesaid program. Program names, as well as all copyright relating to programs, are the exclusive property of ADEUNIS.
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 Please note : do not open the product as there is a risk of electric shock. Please note : for your own safety, you must ensure that the power supply to the equipment is switched off before carrying out any work on it.
IMPORTANT NOTE: the SIGFOX SENSORS can only be started or restarted using a magnet. Description • ADEUNIS ’s SIGFOX SENSORS is a ready-to-use radio transmitter enabling any type of 0-10 V, 4-20 mA or On-Off sensor to be transformed into a wireless sensor. •...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 1.2. Dimensions Values in millimetres 1.3. Electronic board Internal antenna SIGFOX protocol Internal battery RF module Product configuration switches Screw terminals for connection to meters Page of 45...
OPERATION: this is the mode in which SIGFOX SENSORS transmits frames periodically. To switch to this mode of operation, you need to activate the product with a magnet (see §2.6 Product start-up). 1.4.5 Sensors compatibility Examples of sensors tested by Adeunis (non-exhaustive list) Type Name...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 2. PREPARATION AND CONFIGURATION 2.1. Disassembling the casing The product is supplied disassembled such that the lower electronic part can be accessed. This part is where the meter or meters are connected to the screw terminals and where the configuration switches can be accessed.
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 Note: a maximum of 2 sensors may be used in parallel. The user can choose freely between analogue and digital options Analogue sensors require an electric power supply that the battery of the AMR Sensors unit is not able to provide. You must therefore supply the analogue sensor via an external electrical source.
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 2.4. Configuring the SIGFOX SENSORS unit (analog input) In this configuration, the device send a periodic data frame following the choosr setting. This mode is only available when the analog type sensor are selected for both ways.
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 2.5. Configuration the SIGFOX SENSORS unit (digital input) In this configuration, the device send a data frame only when a state is changing on at least one dry contact input. The SIGFOX SENSORS is configured via the combination of switches.
Page 37
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 • Clip the electronic board to the case plate. Make sure the clip is fully engaged in the lug in the board. Clip •...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 • Finish installation by tightening the compression gland nut. Compression gland nut 2.7. Starting the product with a magnet Once configuration of the product has been completed and its installation finalized, the product is ready to be started. The product is started using a magnet placed on the upper part of the product (cf diagram below).
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 3. INSTALLATION AND USE 3.1. Correct positioning of SIGFOX SENSORS transmitters Two rules are essential for optimizing radio range. • The first consists of positioning your product as high as possible. •...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 To optimise fixing to a tube or mast, we recommend removing the Lugs DIN-Rail locking/unlocking lever. To remove it, pull down on the lever until the locking lugs are clear, Clear part then remove the lever.
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 3.2.3 DIN-Rail fixing This system, integrated into the case, lets you fix the SIGFOX SENSORS onto a standard 35mm rail. • To install the case, place the upper inserts on the rail and lower the product to clip it. •...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 4. RADIO FRAMES The SIGFOX SENSORS transmits raw information from meters using the SIGFOX network • A periodic data frame for the analog measure •...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 4.1.2 Uplink - Digital Input Data frame timing for a digital product UPLINK (Case 1) 0x03 0x06 0x01 0x01 Product start Event on Keep alive frame (with magnet) input 1 or 2...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 4.1.4 Status • Low bat error = 1 if supply voltage <= 2.5 V, else 0 • Configuration switch error = 1 if no switch consistency, else 0 •...
All manuals and user guides at all-guides.com SIGFOX SENSORS - Mode d’emploi / User guide version V2.1.1 5. DOCUMENT HISTORY User guide version Contents V2.1.1 Update Declaration of conformity V2.1 Update Declaration of conformity V2.0 Modification Digital Input Function V1.4 Correction function error V1.3 Correction sur chapitre 2.6...