5.4. Closing the casing

Once previous stages have been carried out, you can close the casing of the LoRaWAN US902-928 Pulse
Procedure:
1.
Make sure that the seal is properly positioned on the base
2.
Clip the electronic board onto the casing's base. Make sure that the fastening clip is properly locked into the board's fitting.
3.
Insert the upper part of the casing. Inside this part there are guide rails for the board. Make sure that the board is properly positioned
FR
within these guides.
4.
Once the board is in position, lower the upper cover and lock it onto the casing's base. Strong pressure will enable both parts to be
clipped together and will enable protection level IP67 to be ensured.
5.
Finish the assembly by locking the packing gland's nut in position
1
EN
3/4
Locking clips for the
upper casing

5.5. Starting up the product using a magnet

Once the product has been configured and its assembly
has been finalised, the product is ready to be started
up.
The start-up is carried out using a magnet which you
place on the upper part of the product (cf. the diagram
below). The magnet must be held in position for at least
6 seconds so as to confirm the start-up of the product.
When the magnet is well detected, the green LED lights
up for 1 second.
Once the LoRaWAN US902-928 Pulse unit validates
its start-up, it immediately transmits status frames
followed by a data frame (according the defined
periodicity).
.
Seal
Fastening clip
Packing gland nut
2
Fitting
5
Position of the magnet for
starting up the product