Configuration The Sigfox Sensors Unit (Digital Input); Closing The Casing - ADEUNIS SIGFOX SENSOR Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SIGFOX SENSORS - Mode d'emploi / User guide version V2.1.1

2.5. Configuration the SIGFOX SENSORS unit (digital input)

In this configuration, the device send a data frame only when a state is changing on at least one dry contact input.
The SIGFOX SENSORS is configured via the combination of switches. The following settings can be changed
Transmission interval
Inputs activation (sensors 1 and 2)
The type of sensor connected
If only one of two ways is configured in dry contact, both inputs will works in dry contact
CONFIGURATION TABLE:
Parameter
Value
100ms
Debounce Time
1s
(Only Available
10s
on Digital Input Mode)
1 minute
Sensors 1&2 inactives
Sensor 1 active
Activation of sensor
inputs
Sensor 2 active
Sensor 1&2 actives
Sensor type
Sensor 1&2 Dry Contact
PLEASE NOTE: You must set your switches before activating the meters. Once the fraud wire for each of the meters has been installed and the
SigFox SENSORS has been started via magnet, the configuration with the switchs can no longer be possible.
If the configuration has any difference between the switchs and the product register value, the consistency error bit will be set to on in the
frame. This consistency verification is carried out every minute.

2.6. Closing the casing

Once steps 3.2, 3.3 and 3.4 have been completed, you can close the SIGFOX SENSORS's case.
Procedure:
Make sure the seal is installed correctly on the case plate.
All manuals and user guides at all-guides.com
SW1
SW2
SW3
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
ON
Seal
SW4
SW5
SW6
OFF
OFF
ON
ON
ON
ON
Page
36
of 45
GB