START KI
Circolatore di serie 6 metri / Standard 6 metre circulator / Circulateur de série 6 mètres
Circulador de série de 6 metros / Széria keringtető szivattyú 6 méter / Circulator de serie 6 metri
Cirkulaciona pumpa u serijskoj opremi, 6 metara / Cirkulacijska crpka u serijskoj opremi, 6 metara / Serijska pretočna črpalka 6 metrov
600
550
500
450
400
350
300
250
200
150
100
50
0
0
100
Kit circolatore alta prevalenza (7 metri) / High head (7 metre) circulator kit / Kit circulateur hauteur élevée (7 mètres)
Kit circulador de alta prevalência (7 metros) / Nagy emelőnyomású keringtető szivattyú készlet (7 méter) / Kit circulator de înaltă prevalență
(7 metri) / Komplet cirkulacione pumpe velikog napora (7 metara) / Komplet cirkulacijske crpke velike dobavne visine (7 metara)
Komplet črpalke visokega presežnega tlaka (7 metrov) / Κιτ κυκλοφορητή μεγάλου υπολειπόμενου μανομετρικού ύψους (7 μέτρα)
700
650
600
550
500
450
400
350
300
250
200
150
100
50
0
0
100
[IT] - Circolatore
Le caldaie sono equipaggiate di circolatore già
collegato idraulicamente ed elettricamente, le cui
prestazioni utili sono riportate nel grafico.
Le caldaie sono dotate di un sistema antibloc-
caggio che avvia un ciclo di funzionamento ogni
24 ore con selettore di funzione in qualsiasi po-
sizione.
La funzione "antibloccaggio" è attiva solo se
le caldaie sono alimentate elettricamente.
È assolutamente vietato far funzionare il cir-
colatore senza acqua.
La velocità può essere scelta operando attraver-
so la levetta presente sul circolatore.
A = prevalenza residua (mbar)
B = portata impianto (l/h)
126
All manuals and user guides at all-guides.com
Βασικός κυκλοφορητής 6 μέτρων
200
300
400
500
200
300
400
500
600
[EN] - Circulator
Theboilers are equipped with a circulator already
hydraulically and electrically connected, whose
useful available performance is indicated in the
graph.
The boilers are equipped with an anti-blocking
system which starts up an operation cycle every
24 hours, with the mode selector in any position.
The "anti-blocking" function is active only if
the boilers are electrically powered.
it is strictly forbidden to operate the circula-
tor without water.
The speed can be chosen operating on the lever
found on the circulator.
A = residual head (mbar)
B = system flow rate (l/h)
600
700
800
900
1000
B
700
800
900
1000
B
[FR] - Circulateur
Les chaudières sont équipées d'un circulateur
déjà branché hydrauliquement et électriquement,
dont les performances utiles sont indiquées sur
le graphique.
Les chaudières sont dotées d'un système an-
ti-blocage qui démarrer un cycle de fonctionne-
ment toutes les 24 heures avec le sélecteur de
fonction dans n'importe quelle position.
La vitesse peut être choisie en opérant à l'aide du
levier présent sur le circulateur.
A = hauteur manométrique résiduelle (mbar)
B = débit de l'installation (l/h)
1100
1200
1300
1100
1200
1300
1400
La fonction "antiblocage" n'est active que si
les chaudières sont sous tension.
Il est formellement interdit de faire fonction-
ner le circulateur sans eau.